10
Rev. A / December 2006
PMT-872A Wrist Strap/Footwear Auditor
1. Individually Tes ng Each Conduc ve Sec on: Cuff to Plug
a. Place the PMT-872A toggle switch in the
UP
, Wrist Strap posi on.
b. A ach the wrist strap ground cord to the wrist strap cuff assembly according to the manu-
facturer’s instruc ons.
c. Insert the wrist strap grounding cord phono plug into the “
Dual Cord Input
” receptacle
located on the front panel of the PMT-872A.
d. Carefully holding the cuff assembly, press only one half of the inside cuff surface against
the PMT-872A’s “Press to Test” bu on.
IMPORTANT NOTE
Assuming an acceptable dual conductor wrist strap assembly, if both halves of the cuff
simultaneously contact the “Press to Test” bu on, a false
LOW FAIL
may be indicated. This is
the sign that the system halves are shorted together.
e. If only one half of an acceptable system is being properly tested, you will see the LED’s light
up while a emp ng to automa cally “range”. The LED light sequence will be:
(1)
Ini ally, the
HIGH FAIL
and LOW BATT. LED’s should light briefl y.
(2)
The
HIGH FAI
L LED goes off , the PASS LED comes on and the LOW BATT. LED remains
on.
(3)
The
PASS
LED remains on and the LOW BATT. LED goes off .
(4)
An audible “Beep” begins to sound when the test is completed and the Wrist Strap
is within the acceptable resistance range while being worn.
f. Repeat the procedure with the other half of the cuff assembly and look for the same ac-
ceptable results.
g. If Either Half of the Dual Conductor Wrist Strap Assembly Indicates
HIGH FAIL
, the cuff may
be dirty or damaged, or the conductor and resistor may be greater than 1.0x10
7
ohms.