background image

*

 When working on small or irregular shaped objects, secure with vise or clamps. 

*

 Disconnect the tool when not in use. Avoid unintentional starting. lf the gun shuts down 

during operating, disconnect from the power supply and have gun serviced by authorized 
service personnel. 

*

 To be on the alert! Please pay attention to the work and use common sense when 

operating this tool. Do not operate the tool when you are tired or taking medication or 
drugs that make you drowsy. 

 

WHEN REMOVING PAINT OR VARNISH 

*

 Never use the heat gun in combination with chemical scrapers. 

*

 Clean dry paint or varnish from the nozzle and scrapers after use. It could ignite. 

*

 Use in well-ventilated areas only. Peelings and residue from lead-based paints are 

poisonous. 

 

POWER INFORMATION 

Be sure the power supply you are using agrees with the nameplate marking on the heat 
gun, the guns are designed to run on 220 V 50 Hz, alternating current (ordinary house 
current). Voltage decreases more than 10% can cause loss of power and possible 
overheating. The tool is double insulated for safety. This means there are two separate 
layers of insulation between the operator and the tool's electrical system. 
 
Warning: double insulation does not take the place of normal safety precautions when 
operating the heat gun. Double insulation acts as a safeguard against injury resulting from 
a possible electrical insulation failure inside the tool. Tools built with double insulation are 
not intended to be grounded. Because of this, the gun's power cord is fitted with a 
two-pronged plug suitable for use in any conventional 220 volt electrical outlet. Additional 
ground connections need not be made.   
 
Warning: when servicing double-insulated tools, use only identical replacement parts. 
Replace damaged cords. 
 

LCD Panel   

Intelligent LCD display with memory function: the LCD 
displays previous temperature while power on     
 
1.  Temperature adjust (-) from 100

℃~

650

℃ 

2.  Temperature adjust (+) from 100

℃~

650

℃ 

 
Air volume adjustment switch 

O: Off 
I : 200L / min

 

 

II: 500L / min 

 
 

SS-621Series User’s Manual 

使用說明書

   

2