Pros'Kit MT- 4615 User Manual Download Page 23

22 

4

將電池蓋按原樣裝上。

 

附件

 

包裝袋

 

一個

 

使用說明書

 

一本

 

Summary of Contents for MT- 4615

Page 1: ...MT 4615 Anemometer User s Manual 1st Edition 2016 2016 Prokit s Industries Co Ltd Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 2: ...receiving the anemometer If it should be stored and shipped under hard conditions please confirm whether the meter is damaged Usage The meter should be used in the range of specified ambient temperatu...

Page 3: ...it is not in use The meter will consume small current about 5 A after shutdown If the meter is not to be used for a long period batteries should be removed to prevent damaging the meter Description Th...

Page 4: ...nd speed measurement area setting and air volume measurement Long press for three seconds to enable or disable Auto Power Off function Default is auto power off model after 10mins no operation auto po...

Page 5: ...nd speed greater than 5m s MAX Displays maximum after entering maximum minimum mode MIN Displays minimum after entering maximum minimum mode m Indicates that the current area setting unit is square me...

Page 6: ...ation environment Relative humidity 0 85 RH no moisture condensation Temperature 0 C 40 C no moisture condensation Detector fan operation environment Relative humidity 0 95 RH no moisture condensation...

Page 7: ...e only knots Measuring range Resolution Accuracy 0 80 58 30 knots 0 01 knots 2 0 reading 50 digital 58 30 77 70 knots For reference only 3 2 5 mil h Measuring range Resolution Accuracy 0 90 67 20 mil...

Page 8: ...s body of backlight is LED with large operating current Frequently using backlight will shorten battery life Do not use backlight when unnecessary When the battery voltage 7V the low battery symbol wi...

Page 9: ...play on the screen Use the MAX MIN and UNIT keys to adjust value and unit after adjusting area unit m ft then press MAX MIN key There should be an audible buzz indicating that area input is completed...

Page 10: ...elect the measurement unit you require CMS CMM CFM Replacing battery If the sign appears this indicates that the battery should be replaced Power off the meter and remove the battery cover Replace the...

Page 11: ...10 MT 4615...

Page 12: ...11 1 2 1 2 3 4 5 1 2...

Page 13: ...12 3 4 5 5 A 1 2 3 4 5...

Page 14: ...13 1 2 3 FUNC 4 5 UNIT 6 7 HOLD 8...

Page 15: ...14 HOLD FUNC 10 MAX MIN UNIT m ft m s km h mil h ft s ft m knots CMS CMM CFM...

Page 16: ...15 HOLD VEL FLOW AREA SLOW 5m s FAST 5m s MAX MIN m ft CMM CMS CFM Knots 1850 ft s ft m m s Km h mil h...

Page 17: ...16 2 50d 18 28 70 2000m LCD 9999 0 4 LCD 9V 1 6F22 0 85 RH 0 40 0 95 RH 20 80...

Page 18: ...17 0 80 RH 10 50 170 X85 X40 mm 23 5 75 m s 0 80 30 00 m s 0 01 m s 2 0 50 30 00 40 00 m s km h 1 40 108 00km h 0 01km h 2 0 50 108 0 144 0 km h ft s 1 30 98 50ft s 0 01 ft s 2 0 50 98 50 131 20ft s...

Page 19: ...80 58 30knots 0 01knots 2 0 50 58 30 77 70knots mil h 0 90 67 20mil h 0 01mil h 2 0 5 67 20 90 00 mil h ft m 78 5900ft m 1ft m 2 0 5 5900 7874ft m CFM 0 9999 0 9 999 ft CMM 0 9999 0 9 999 m CMS 0 9999...

Page 20: ...19 HOLD HOLD FUNC MAX MIN UNIT 15 1 LED 2 7V 7V...

Page 21: ...20 VEL 1 2 UNIT m s km h mill h ft s ft m knots FUNC AREA MAX MIN UNIT m ft MAX MIN...

Page 22: ...21 FUNC FLOW 1 2 UNIT CMS CMM CFM 1 2 3...

Page 23: ...22 4 1 2...

Page 24: ...23 2016 Prokit s Industries Co Ltd All rights reserved 2016001 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Reviews: