28
10.3.7 Counter reset using an external signal
►
Select [ou2] and set In.D.
►
Select [DIn2] and set the counter reset signal:
HIGH = reset for high signal
LOW = reset for low signal
+EDG = reset for rising edge
-EDG = reset for falling edge
10.4 Settings for temperature monitoring
10.4.1 Limit monitoring temperature (OUT2)
►
Select [SEL2] and set TEMP.
►
Select [ou2] and set the switching function: Hno, Hnc, Fno or Fnc.
►
Select [SP1] and set the upper temperature limit.
►
Select [rP2] and set the lower temperature limit.
10.4.2 Analog output temperature (OUT2)
►
Select [SEL2] and set TEMP.
►
Select [ou2 ] and set the analog function: I (4...20 mA) or U (0...10 V).
►
Select [ASP2] and set the temperature value at which the minimum current or voltage
value is provided.
►
Select [AEP2] and set the temperature value at which the maximum current or voltage
value is provided.
10.5 User settings (optional)
10.5.1 Standard unit of measurement for flow rate
►
Select [uni] and set the unit of measurement.
The setting only has an effect on the flow rate value. The volumetric totalizer is auto-
matically displayed in the unit of measurement providing the highest accuracy.