6
Resistance
Measurement range
Distinguish
ability
Accuracy degree
6k
0.001k
0.8% r3 word
60k
0.01k
600k
0.1k
6M
0.001M
10M
0.01M
Overload protection: 600V DC or AC (effective value)
Line on-off test
Measurement range
Distinguish
ability
Functions
1
If the resistance of
circuit being
measured is less than
50
±30
, then the
beeper in the meter
may sound.
Overload protection: 600V DC or AC (effective value)
4.Operation Guide
4.1 Readings Hold
During the measuring process, if the readings are required to hold, slightly
touch
key ,the display value will be locked, slight press
key again to
cancel readings hold.
4.2 Backlight
1
)
In the process of measurement, if the ambient light is too dim, causing reading
difficulties, press
key for more than 2s, open Back Light and it will
automatically off after about 1 minute.
2
)
During the process if press
key for more than 2s, then the Back Light will
be turned off.
4.3 Auto Power Off
1
)
If after 10 minutes when the meter is on without any operation, it will go into
hibernation and automatically shut down to save power. Before the meter off,
there will be one sound of the buzzer to remind every 1 minute.
2
)
Press any key after auto power off to wake the meter into working status.
9