Trial Operation Float Switch 

 

1.   Direct the float switch downward. 

2.   Raise the float to its highest location. This will cause the pump to start. 

3.   Next, return the float switch to its original position. This will cause the pump to stop 

4.   Perform steps (2) and (3) consecutively two or more times to verify the operation. 

 

Operation 

HOT SURFACE HAZARD 

 

 

Do not touch the product with bare hands during or immediately after the operation, as the product may become 

very hot during operation. Failure to observe this caution may lead to being burned. 

 

CAUTION 

 

 

Do not run the pump dry or operate it with its gate valve closed, as doing so will damage the 

product, which may lead to electrical leakage or electrical shock. 

 

Pollution of the liquid could occur due to leakage of lubricants. Never use the product for potable 

water. 

 

1.   Pay attention to the water level during operation. 

2.   Do not operate the pump at the lowest water level longer than 30 minutes. For details on the lowest water  

      level, refer to the dimensioning drawing, which is provided separately. 

3.   If the built-in motor safety is activated, the pump will shut down and restart automatically. 

 

 

Regular checkups and preventive maintenance will ensure a more reliable and safe operation. An initial 

inspection of the pump within 3 to 4 months after installation is recommended. 

Subsequent inspections/maintenance can be carried out every 6 months. 

 

WARNING 

 

 

Always disconnect and lock out the pump from the power supply before inspecting the pump. 

 

Make sure that the pump cannot roll or fall over to injure people and damage property. 

 

Rinse the pump thoroughly with clean water before working on the pump. 

 

The pump should not be activated if it is partially dismantled. 

 

Maintenance Requirements 

 

 

Allow all system and pump components to cool before handling them. 

 

Make sure that the pump and its components have been thoroughly cleaned. 

 

Inspect and verify that there is no damage on the pump exterior, and that the bolts and nuts have 

not loosened. 

 

Do not open any vent or drain valve or remove any plugs while the system is pressurized. 

 

Make sure the pump is isolated from the system. 

 

Maintenance General Guidelines 

 

 

Clean all parts thoroughly, especially O-rings grooves. 

 

Change all O-rings, and gasket. 

 

During assembly or service of the pumps, it is recommended that the screws be tightened to 

approximately 6- Nm (4.5 6 ft-lb). The tightening torque ensures the parts are correctly fastened and 

that the pump will operate as intended 

Maintenance and Inspection

 

 

 

Summary of Contents for GOCUT Series

Page 1: ...2 Download the manual in your preferred language scan the QR code...

Page 2: ...Float Switch Loction Installation Requirement Electrical Connection______________________________________________________________ 8 Connection Requirements External Protection Devices Grounding Earth...

Page 3: ...s and health problems damage to the product and or product malfunction Hazard Notice Symbols DANGER A hazardous situation which if not avoided will result in death or serious injury WARNING A hazardou...

Page 4: ...f long exposure to noise Never run the pump without water do not operate the pump out of water or insufficient water Do not use the pump if the power cable is damaged If you have any questions please...

Page 5: ...se Turn the impeller by hand before using the pump Check the seals and the cable entry Additional information on the product specific information e g dimensions specifications performance curves for t...

Page 6: ...und the pump working area Check for any explosion risk before pipe welding or use of any electrical hand tools Remove any remaining debris from the inlet piping system before installing the pump CAUTI...

Page 7: ...OTICE For the water level required for operating the pump refer to the pump s dimensional drawing that can be obtained from our representative or company 6 Make sure that the impeller rotation is corr...

Page 8: ...alog pressure sensor Two additional safety float switches can be installed in the dedicated Control System for high level and dry running alarm The thermal contacts thermistors must be in use The cabl...

Page 9: ...to Operation Never operate the pump without safety devices installed Never operate the pump with the discharge valve closed Make sure that all safety guards are in place and secure Make sure you have...

Page 10: ...tation of the impeller If the starting jerk is counterclockwise seen from above the direction of its rotation is correct If the direction of rotation is incorrect two of the wires should be switched c...

Page 11: ...checkups and preventive maintenance will ensure a more reliable and safe operation An initial inspection of the pump within 3 to 4 months after installation is recommended Subsequent inspections maint...

Page 12: ...13 CUTTING HAZARD Worn impellers often have very sharp edges Be very careful when replacing them Troubleshooting...

Page 13: ...ate 5 Mech Seal 12 Strainer 6 Seal bracket 13 Base plate 7 Oil seal No enomination No Denomination 1 Motor 7 Agitator 2 Mech Seal 8 Wear plate 3 Pump casing 9 Inlet plate 4 Oil seal 10 Strainer 5 Shaf...

Page 14: ...ischarge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller enomination No Denomination 1 Motor 7 Pump casing 2 Mech Seal 8 Flange 3 Pump casing 9 Discharge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller Part Lis...

Page 15: ...16 enomination No Denomination 1 Motor 7 Pump casing 2 Mech Seal 8 Flange 3 Pump casing 9 Discharge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller Part List SAVVY JUMBO BASE Pumps 4 5...

Page 16: ...17...

Page 17: ...ion Examples CP 1026 2018 November 1026th pump BS 1496 2017 August 1496th pump BN 1135 2017 December 1135th pump B 2017 P November C 2018 Q October D 2019 R September E 2020 S August F 2021 T July G 2...

Page 18: ...UANGHUA RD DASHE DISTRICT KAOHSIUNG CITY 815 TAIWAN TEL 886 7 351 2306 MADE IN TAIWAN REV MN 2021 01 2021 PRORIL The original instruction is in English All non English instructions are translations of...

Reviews: