background image

2/4 

INQL3-MAR09 
03/03/09 WW 

Pneumatic Connections  

CAUTION: 

USE ONLY THE THREAD SEALANT 

PROVIDED.  OTHER SEALANTS SUCH AS PTFE 
TAPE AND PTFE PASTE CAN MIGRATE INTO THE 
FLUID SYSTEM CAUSING FAILURES. 

 

1.  The valve can be mounted in any position without af-

fecting performance. A variety of mounting brackets 
(QBT-01, QBT-02, and QBT-03. SEE ordering info) 
can be used to attach valve to a panel or wall surface. 

2.  A typical 40 micron in-line filter is recommended on 

the inlet of the QL3 valve. This is available from Pro-
portion-Air as part number FPP-2. 

3.  A 1/16” plug is supplied with the valve.  It can be used 

to plug the “Alternate Exhaust Port” if the exhaust 
media should be captured or when the valve is used for 
vacuum or vacuum through positive pressure control.  
See Figure 1 for port location. 

Positive Pressure Units

 

1.  Connect supply pressure to the “I” port (Figure 1) not 

to exceed rated supply pressure.  (See TABLE 1)  

2.  Connect the outlet “O” port (Figure 1) to the device 

being controlled. 

3.  The “E” exhaust port can be plumbed to a point out-

side the work area, fitted with a muffler or left open to 
atmosphere as the application dictates. 

4.  Proceed with electrical connection. 

 

CONNECTION PROCEDURE

 

Electrical Connections  

1.  Turn off all power before making electrical connec-

tions.   

2.  Identify the valve’s command input and analog output 

using the calibration card included in the package and 
the ordering information section on the last page of 
this sheet. 

3.  Proceed to the appropriate section corresponding to the 

type of valve being installed. 

NOTE:  ALL COLOR CODES RELATE TO QL3'S 
ORDERED FROM THE FACTORY WITH PRE-
ASSEMBLED QBT-C-X CABLES.

 

Voltage Command Valves (TFEE) 

All voltage command QB3's use a single ended command, mean-
ing the DC Common serves as both the power and command 
common. 

Current Command Valves (TFIE) 

All current command QL3's use a differential current loop scheme 
(not isolated), meaning current flow is from Pin 4 to Pin 2 on the 
QL3 valve.  Some applications may require the common of the 
power supply that provides loop power for the 4-20mA command 
to be tied to power supply common.  The following diagram 
shows the correct connection for conventional current flow.   

PIN 2 {BLUE} 
4-20MA COMMAND (-)

 

PIN 4 {WHITE} 
4-20MA COMMAND (+)

 

PIN 1 {GREEN} 
DC COMMON (-)

 

PIN 6 {BLACK} 
DC POWER (+)

 

PIN 4 {WHITE} 
0-10 Vdc COMMAND (+)

 

PIN 1 {GREEN} 
DC COMMON (-)

 

PIN 6 {BLACK} 
DC POWER (+)

 

    POWER AND  
    COMMAND

 

Current Monitor Valves  
(TFEC or TFIC SINKING OUTPUT) 

Use the following wiring diagram for QL3 valves with a current 
sinking monitor output. 

PIN 6 {BLACK} 
DC POWER (+)

 

PIN 5 {RED} 
4-20mA  MONITOR (-)

 

MA 

METER 

Voltage Monitor Valves  
(TFEE or TFIE) 

Use the following wiring diagram for QL3 valves with a voltage 
monitor output. 

PIN 1 {GREEN} 
DC COMMON (-)

 

PIN 5 {RED} 
0-10V MONITOR (+)

 

METER 

PIN 6 {BLACK} 
DC POWER (+)

 

Current Monitor Valves  
(TFES or TFIS SOURCING OUTPUT) 

Use the following wiring diagram for QL3 valves with a current 
sourcing monitor output. 

MA 

PIN 1 {GREEN} 
DC COMMON (-)

 

METER 

PIN 5 {RED} 
SIGNAL OUT

 

Courtesy 

of 

CMA/Flodyne/Hydradyne 

 Motion 

Control 

 Hydraulic 

 Pneumatic 

 Electrical 

 Mechanical 

 (800) 

426-5480 

 www.cmafh.com

Summary of Contents for QL3 Series

Page 1: ...sure that is being sensed and fed back to the control circuit any mechanical hysteresis of the air piloted volume booster is automatically compensated for This allows for our extraordinary accuracy and repeatability The QL3 improves and builds on the proven Proportion Air QB3 series high performance by using a current driven variable orifice solenoid valve and a unique analog PID circuit This vari...

Page 2: ...age of this sheet 3 Proceed to the appropriate section corresponding to the type of valve being installed NOTE ALL COLOR CODES RELATE TO QL3 S ORDERED FROM THE FACTORY WITH PRE ASSEMBLED QBT C X CABLES Voltage Command Valves TFEE All voltage command QB3 s use a single ended command mean ing the DC Common serves as both the power and command common Current Command Valves TFIE All current command QL...

Page 3: ... levels Verify the accuracy of your measuring equipment before re calibrating Consult factory if you have any questions or require assistance For valves ordered with MAX calibrated pressure Max inlet pressure 5 through 10 psi positive 15 psig 1 bar 10 1 up to 30 psig 0 70 up to 2 bar 35 psig 2 4 bar 31 up to 100 psig 2 1 up to 7 bar 110 psig 7 6 bar 101 up to 150 psig 7 up to 10 3 bar 165 psig 11 ...

Page 4: ...H REGARD TO CONSEQUENTIAL DAMAGES WARRANTIES OF MERCHANTABILITY DESCRIPTION AND FITNESS FOR A PARTICULAR PURPOSE WARNING Installation and use of this product should be under the supervision and control of properly qualified personnel in order to avoid the risk of injury or death ORDERING INFORMATION QL 3 T F E E xxx A Ø 8 SERIES SIZE 3 1 4 NPT Ports CONTAINER COMMAND INPUT MONITOR SIGNAL MAXIMUM C...

Reviews: