The lock does not need lubrication!

 

The  warranted  operation  period  is  12  months  from  the  date  of  sale  but  not 
longer than 18 months from the day of acceptance by the manufacturer’s QCD.

 

9.

 

MAINTENANCE

 

Maintenance of the lock is performed at least once every two months and includes: 

 

Visual inspection of the lock to check reliability of fastening. If necessary, tighten fasteners 
of the lock and the latch. 

 

Checking the proper position of the latch. (see section 8). 

10.

 

STORAGE AND TRANSPORTATION

 

Prior  to  putting  into  operation,  the  locks  must  be  stored  in  the  manufacturer’s  packing,  in 

rooms with an ambient temperature 

of -

30 to +50 °С

 and a relative humidity not higher than 98% 

at 25º С in compliance with storage conditions as per GOST 15150-69. 

Locks transportation conditions must comply with group C as per GOST 23216-78 in terms of 

exposure to mechanical factors, and Ж2 as per GOST 15150-69 in terms of exposure to climatic 
factors. 

11.

 

SAFETY REQUIREMENTS

 

The design of the locks ensures safety of personnel involved in mounting and maintenance. 
Due to low DC supply voltage, the products correspond to class III as per ГОСТ 12.2.007.0-

75 and are electrically safe. 

Fire safety of the locks is ensured by use of non-combustible or hardly combustible materials, 

and low supply voltage. 

12.

 

DISPOSAL

 

The product is not hazardous for human life and health or for the environment; disposal after 

its service life is performed without taking any special measures for environment protection. 

13.

 

WARRANTY LIABILITIES

 

The  manufacturer,  ETC  PROMIX  LLC,  warrants  conformity  of  Promix-SM308  locks  to 

requirements of current Technical Specifications provided that transportation, storage, installation 
and operation rules established in this Manual are followed. 

Within the period of warranty, ETC PROMIX LLC undertakes to repair defective products free 

of charge. Expenses for transporting the product to the place of repair and back will be borne by 
the Buyer. 

Warranty liabilities do not cover any defects and damages caused by: 

 

Improper maintenance by the Buyer; 

 

Use of the product under conditions that do not comply with the operation requirements; 

 

Mechanical damages or disassembly of the products by the Buyer; 

 

Non-observance of the transportation and storage rules. 

Summary of Contents for Promix-SM308.10.1

Page 1: ...the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the list of lock modifications that can be ordered see 5 2 The color of the product is shown on the sticker stuck to the box after the product name Series colors Silver White Brown Black Other colors are p...

Page 2: ...dle on the door The spring loaded pusher of the lock is connected to the door position sensor The operating principle of the sensor is described in 6 3 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The lock operation environment must be explosion safe free of current conducting dust or gases that cause metal corrosion and destroying insulation of current conductors and electric elements free of curren...

Page 3: ... than s 1 10 Minimum pause between pulses s 15 20 Built in sensors door position sensor Maximum switch current of the sensor DC А 0 2 Maximum switch voltage of the sensor DC V 24 Sensor output signal type dry contact Lock weight not more than kg 0 27 Holding force not less than kg 250 Initial latch pushing out force not less than kg 1 2 Manufactured against order Lock and latch overall and mountin...

Page 4: ...m the locker wall edge 3 Connect the lock to the power supply see 6 3 4 Insert the latch into the lock 5 Test operability of the lock as voltage is applied the lock must push out the latch 6 Fasten the latch to the door at a distance of 20 3mm from the base edge of the lock see Fig below 7 Test operability in door closing Fastening self tapping screws 15 Locker wall edge Base edge of the lock 3 ho...

Page 5: ...r a switch button is generally used The controller is mounted in accordance with its certificate Purpose of terminals 1 2 Lock energizing 3 Normally open contact of the sensor 4 Common contact of the sensor 5 Normally closed contact of the sensor Connect the lock power wires adhering to the following polarity Terminal 1 positive pole of the power supply Terminal 2 negative pole of the power supply...

Page 6: ... criticality level the purpose of the access restriction regime and other factors the presence of security providers video surveillance etc 2 To prevent deformations of the door due to attempts to open the door with the lock closed it is recommended to mount the lock in the area of the door handle 3 It is recommended to install the lock together with a door closer this reduces impact load on the l...

Page 7: ... in mounting and maintenance Due to low DC supply voltage the products correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed w...

Page 8: ...ctual basis 14 ACCEPTANCE AND PACKING CERTIFICATE Electromechanical lock Promix SM308 in quantity of ____ pieces 1 pc by default bearing the manufacturing date and QCD mark on the body was manufactured and accepted in compliance with Specifications ПШБА 304268 003 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PRO...

Reviews: