Type
Minimum pump capacity at maximum back pres‐
sure
Maximum
stroke
rate
Suction lift Permissible
priming
pressure,
suction side
Connector
size
bar
psi
l/h
gph
Strokes/mi
n
m WS
bar
R"-DN
12017 PVT
12
174
20
5.4
88
7
1
3/4" - 10
12017 SST
12
174
20
5.4
88
7
1
3/4" - 10
12035 PVT
12
174
42
11.1
172
7
1
3/4" - 10
12035 SST
12
174
42
11.1
172
7
1
3/4" - 10
10050 PVT
10
145
60
15.9
246
7
1
3/4" - 10
10050 SST
10
145
60
15.9
246
7
1
3/4" - 10
10022 PVT
10
145
26
7.0
88
6
1
3/4" - 10
10022 SST
10
145
26
7.0
88
6
1
3/4" - 10
10044 PVT
10
145
52
13.9
172
6
1
3/4" - 10
10044 SST
10
145
52
13.9
172
6
1
3/4" - 10
07065 PVT
7
102
78
20.6
246
6
1
3/4" - 10
07065 SST
7
102
78
20.6
246
6
1
3/4" - 10
07042 PVT
7
102
50
13.2
88
3
1
1" - 15
07042 SST
7
102
50
13.2
88
3
1
1" - 15
04084 PVT
4
58
100
26.6
172
3
1
1" - 15
04084 SST
4
58
100
26.6
172
3
1
1" - 15
04120 PVT
4
58
144
38.0
246
3
1
1" - 15
04120 SST
4
58
144
38.0
246
3
1
1" - 15
All figures refer to water at 20 °C.
The suction lift applies to a filled suction line and filled liquid end - when
installed correctly.
Data
Value Unit
Reproducibility
±2 % *
* - when installed correctly, under constant conditions, at least 30%
stroke length and water at 20 °C
15.2 Viscosity
The liquid ends are suitable for the following viscosity ranges:
Design
Viscosity
Standard
0 ... 200 mPas
With valve springs
200 ... 500 mPas
With valve springs and suction-side
feed
500 ... 1000* mPas
* Only when the installation is correctly adjusted.
S1Ba with 60 Hz operation
Precision
Technical data
60