![ProMinent Duodos 100 PPS Assembly And Operating Instructions Manual Download Page 13](http://html.mh-extra.com/html/prominent/duodos-100-pps/duodos-100-pps_assembly-and-operating-instructions-manual_1617039013.webp)
max. 7 bar
Compressed air remote outlet
Optional
Optional
Optional
Liquid
inlet
Outlet of
drainage valve
Compressed air
Compressed air remote outlet
A2739
Fig. 1: Recommended installation with a compressed air remote outlet as an option
Connect a hose to the new outlet opening and install the silencer
on the end of the hose. Use a hose with the same diameter as the
diameter of the outlet opening 3/8” NPT.
An optional kit is needed for the compressed air remote outlet.
1.
Uncover the compressed air outlet opening of the pump.
Use a hose with the same diameter as the diam‐
eter of the outlet opening.
2.
Connect a hose to the new outlet opening.
3.
Install the silencer at the end of the hose.
4.
Position the end of the hose with the silencer at a suitable
place, e.g. in a protective casing.
Compressed air remote outlet with
silencer
Assembly