ProMinent DULCOMARIN 2 Assembly And Operating Instructions Manual Download Page 1

DULCOMARIN II

Function extension with F module

Assembly and operating instructions

A1234

Target group for these assembly and operating instructions: trained and qualified personnel

EN

Only valid in conjunction with the complete operating instructions for DULCOMARIN II

Part number 985358

Version: BA DC 086 11/16 EN

Please carefully read these operating instructions before use. · Do not discard.

The operator shall be liable for any damage caused by installation or operating errors.

The latest version of the operating instructions are available on our homepage.

Summary of Contents for DULCOMARIN 2

Page 1: ...l EN Only valid in conjunction with the complete operating instructions for DULCOMARIN II Part number 985358 Version BA DC 086 11 16 EN Please carefully read these operating instructions before use Do...

Page 2: ...ation Warning information include detailed descriptions of the hazardous situation The following symbols are used to highlight instructions links lists results and other elements in this document Tab...

Page 3: ...cuit 19 5 3 3 Backflow shut off valve 20 5 4 Lowering the water level 20 5 5 Water flow circulation flow control 21 5 6 Water level control 21 5 6 1 Single stage level function 22 5 6 2 Two level func...

Page 4: ...flow shut off valve n Lowering of the water level during standby operation n Circulation flow control Flowcontrol n Water level control n Sample water valve n Heating function Heating control heat exc...

Page 5: ...ol variable circulation circulating pump filtration circuit 2 Iout2 CntrlChlorination Control variable raise chlorine dosing Iout2 Cntrl pH_increase Control variable raise pH value Iout2 Cntrl pH_redu...

Page 6: ...JetStream on off Switches the JetStream counterflow system K1 K5 Neck shower on off Switches the neck shower on off K1 K5 Massage on off Switches the massage nozzles on off K1 K5 Backwash EM STOP Back...

Page 7: ...1 s 1 s Gutter cleaning 1 s 25 s JetStream feedback 1 s 1 s Neck shower feedback 1 s 1 s Massage pump feedback 1 s 1 s 2 5 Switching of inductive loads If you connect an inductive load i e a consumer...

Page 8: ...gh the load The magnitude of the capacitor is determined using the following equation C k IL k 0 1 2 dependent on the application Only use capacitors of class X2 Units R Ohm U Volt IL Ampere C F If co...

Page 9: ...inal allocation variants 2 6 1 Private pool possible terminal allocation A1261 I II III IV V VI VII VIII IX X XI Fig 4 Private pool possible terminal allocation I Frequency converter FU II Level switc...

Page 10: ...hout a sub folder 2 Minimum requirements of the photos JPEG n The aspect ratio e g 16 9 or 3 2 of the photo must cor respond to that of your output equipment e g monitor n The photograph resolution sh...

Page 11: ...1 pool_2 pool_3 pool_4 pool_5 pool_6 pool_7 pool_8 pool_9 pool_10 JetStream x x x x Massage pump x x x x Neck shower x x x x Cover CLOSE x Under water light x Attraction is ON x ON Attraction is ON OF...

Page 12: ...the ENTER key in the continuous display of the DUL COMARIN II You are now taken to the central menu item Servomotor not ready 6 00 7 12 LIST CONFIG PARAM CAL HELP SD System free Set Dosing Cl A1257 t...

Page 13: ...Type NO Low flow contact SAVE CONFIG SERVICE A1258 Type NO Type NO Type NO Type NO Level max Level Alarm Backwash 1 First filtrate 1 Water top up Heating enable JetStream Underwater light Cntrl circu...

Page 14: ...enu appears 9 In the configuration menu use the vertical arrow keys to select the necessary function and enter the necessary control values Press the ENTER key after each change 10 Finally to confirm...

Page 15: ...top up Heating enable JetStream Underwater light Cntrl circulation 1 free Circ 1 Fig 12 Configuration menu of the DULCOMARIN II 11 Press the F2 key The service menu appears In this service menu you c...

Page 16: ...sing an addi tional module The times for the circulation must be set with the F4 CONFIG F2 OPTION TIMER If no times are set then the circula tion will not run automatically To control a 230 V circulat...

Page 17: ...ppear on the display 3 Set the Filtration speed in normal operation The filtration speed is calculated from the flow rate filter sur face For private applications set a filtration speed of up to 50 m...

Page 18: ...n rate is reached the controller does not lower the rate any further from this level If you have deactivated redox control so called step lowering is active Here two values must be entered Circulation...

Page 19: ...l functions to each relay is not universally possible Please observe our allocation suggestion in the appendix of the operating instructions In the appendix you can find a series of the most appropria...

Page 20: ...to a cleaning process ensuring that any turbidity in the swimming pool is excluded This valve is connected to termi nals P2 P7 and then configured in the operating menu of the Dulcomarin II 5 4 Lower...

Page 21: ...in operation Measure Always return the system to AUTO mode so that all safety equipment is active Pressing the Start Stop key resets all existing errors The system is once more in AUTO mode In the eve...

Page 22: ...t a filling time of 0 8 minutes 5 6 2 Two level functions single stage and overflow alarm This function comprises a single stage level function and a forced switching of the circulating pump at Level...

Page 23: ...the top up water solenoid valve while if the contact is reached an alarm message is output If the contact is activated during a standstill Circulating operation pause of the circulating pump then the...

Page 24: ...other energy carriers via a heat exchanger if this is required Connection of the F module takes place at the terminals P2 P7 The heating system must be activated in the M module so that it can be set...

Page 25: ...culation Digital input and MV active The switch makes a contact Circula tion off metering off and switch on delayed The solenoid valve control and the potential free contact must be wired together and...

Page 26: ...ition Roll cover completely open must be wired to the digital inputs K01 K05 All active actions stop if the cover is being closed or is closed Solely the attraction Underwater light can be manually sw...

Page 27: ...hed If a massage function is activated then the corresponding symbol appears in the Dulco marin II visualisation and the key naming is the same as the Massage nozzle attraction 5 10 5 Underwater light...

Page 28: ...ation quantity In this way you receive a precise indication of the flow on the Dulcomarin II display To achieve an overview of the quantity of the fresh water top up there is an option permitting elec...

Page 29: ...rated in Manual mode Backwashing FW Lev OK FW Time Start Liquid level level measure ment Fresh water top up is also started with a filling time FW Stop Liquid level level measure ment Fresh water top...

Page 30: ...he action SET Backwasch Emergency STOP Pumping system is faulty If the pumping system reports a fault then no backwashing is carried out until this fault is cleared DELETE Backwash Emergency STOP Pump...

Page 31: ...Part number Quantity Electrical filter control unit 733849 1 Filter control cover 1041840 1 PT bolt KA35x10 Torx 1001364 5 Terminal diagram label 1042906 1 Nameplate 1025496 1 Folding box 267x216x64...

Page 32: ...operation no more than insignificant spikes are to be expected Terminal strip XP1 Pin Signal Function 1 L Phase 2 N Neutral conductor 3 PE Protective earth conductor On board fuses n F2 0 63 ampere sl...

Page 33: ...ting current max 30A for 0 5s Ohmic and inductive up to cos phi 0 4 2 N 3 PE XR4 1 L switched Output relay 230 V feeding R C circuit and varistor fuse F6 Max 1100VA 5A starting current max 30A for 0 5...

Page 34: ...r interfaces 4 XK2 1 Digital input 5 Max 10 kHz Potential free mechan ical contact or open col lector Isolated to the C and all other interfaces 2 3 4 Description Value Insulation voltage 500 Vpp max...

Page 35: ...max Output voltage max 18V idle Overvoltage resistant up to 50V no function for output current 0mA at 21 5mA up to 30V otherwise overheating of the control transistor is possible Ripple max 450 ohm a...

Page 36: ...e digital inputs allocated 5 Question How are the mA outputs allocated 5 Question How are the outputs allocated 6 Question How are the terminals of the F module allocated 5 Question How do I clear an...

Page 37: ...37...

Page 38: ...38...

Page 39: ...39...

Page 40: ...985358 2 en_GB 2016 ProMinent GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com...

Reviews: