1.2 Identity Code for DULCO
®
flex DFAa 008
Identity code
DFAa DULCO
®
flex DFAa 008
Type
008 DFAa 008, with 8 mm hose, wall thickness 2.4 mm,10 ml/revolution
Power end/drive
000 Pump without power end/drive
Reduction gear system / 3 x 230 / 400 VAC
B10 0.12 kW, 14 rpm, 8.4 l/h, 2 bar
B11 0.12 kW, 35 rpm, 21 l/h, 2 bar
B12 0.12 kW, 70 rpm, 42 l/h, 2 bar
B13 0.18 kW, 93 rpm, 55.8 l/h, 2 bar
B14 0.18 kW, 140 rpm, 84 l/h, 2 bar
Manual adjustment gears / 3 x 230 / 400 VAC
B21 0.12 kW, 10.9 ... 57 rpm, 6.5 ... 34.2 l/h, 2 bar
B22 0.25 kW, 34 ... 176 rpm, 20.4 ... 105 l/h, 2 bar
Gear motor with integrated frequency converter / 1x 230 VAC
B31 0.18 kW, 13 ... 130 rpm, 7.8 ... 78 l/h, 2 bar, 7 ... 70 Hz
Gear motor (external frequency converter required) / 3 x 230 / 400 VAC
B41 0.18 kW, 4 ... 105 rpm, 2.4 ... 63 l/h, 2 bar, 3 ... 75 Hz
Hose material
A Norprene
®
A60G
B Norprene
®
A60F
C Solva
®
D Silicone
Base plate
0
Base plate, lacquered steel
1
Base plate, stainless steel
Batch control
0
No batch control
R
With batch control
Special version of motor
0
Standard (3 phase) 3x230/400 VAC
D
Single-phase motor, 0.12 kW (only for B10 ... B12) 1x230
VAC
E
Single-phase motor, 0.18 kW (only for B13 ... B14) 1x230
VAC
Pump head
0
Standard with one pump head
Product identification
6
Summary of Contents for DULCO flex DFAa
Page 5: ...Identity code C Double head version Approvals 01 CE mark Product identification 5...
Page 7: ...Identity code C Double head version Approvals 01 CE mark Product identification 7...
Page 20: ...10 Open all valves Maintenance 20...
Page 28: ...12 2 Performance curves A0510 Fig 3 DFAa 003 3 2 mm DFAa 008 8 0 mm DFAa Technical Data 28...