25
Pr
o
Minent
®
Decommissioning and disposal / Technical data
9
Decommissioning and disposal
IMPORTANT
• When decommissioning a pump, clean all traces of chemicals
and dirt from the housing and particularly the liquid end.
• Observe all relevant disposal directives for your area
(particularly with regard to electronic waste)
10
Technical data
Output diagram at 180 strokes/min
* Suction lift with filled suction line and liquid end
** Suction heights with clean as well as moistened valves, with
metering medium water (20
°
C), 100% stroke length, max. stroke
frequency, free outlet or opened vent valve and properly installed
piping system.
Leistungstabelle bei 240 Hüben/min
Pump
min. output at
min. output at mean
max. no.
Conn. size
Suction
Suction
Permissible
type
maximum
backpressure
of strokes
outer Ø •
height*
height**
pre-pressure
backpressure
inner Ø
suction side
Strokes/
bar
l/h
ml/stroke
bar
l/h
ml/stroke
min
mm
m WC
m WC
bar
1001
10
1.0
0.069
5
1.3
0.09
240
6x4
6
1.8
8
1602
16
1.5
0.10
8
1.9
0.13
240
6x4
6
2.0
8
1003
10
2.7
0.19
5
3.5
0.24
240
6x4
5
2.5
5
0705
7
5.2
0.36
3.5
5.9
0.41
240
6x4
4
3.0
4
0311
3
11.4
0.79
1.5
14.4
1.0
240
8x5
2
2.0
1
0220
1.5
19.9
1.38
1.0
23.4
1.63
240
8x5
1.5
1.5
0.5
Pump
min. output at
min. output at mean
max. no.
Conn. size
Suction
Suction
Permissible
type
maximum
backpressure
of strokes
outer Ø •
height*
height**
pre-pressure
backpressure
inner Ø
suction side
Strokes/
bar
l/h
ml/stroke
bar
l/h
ml/stroke
min.
mm
m WC
m WC
bar
1000
10
0.74
0.07
5
0.8
0.08
180
6x4
6
1.8
8
1601
16
1.1
0.1
8
1.4
0.13
180
6x4
6
2.0
8
1002
10
2.1
0.19
5
2.6
0.24
180
6x4
5
2.5
5
0704
7
3.9
0.36
3.5
4.5
0.42
180
6x4
4
3.0
3
0308
3
8.5
0.79
1.5
10.8
1.00
180
8x5
2
2.0
1
0215
1.5
14.9
1.38
1.0
15.5
1.4
180
8x5
1.5
1.5
0.5
BA_CO_016_06_07_4spr.p65
21.06.2007, 12:48 Uhr
25
Summary of Contents for CONCEPT PLUS 0215
Page 15: ...15 ProMinent Konformit tserkl rung BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 15...
Page 16: ...16 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 16...
Page 29: ...29 ProMinent Conformity declaration BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 29...
Page 30: ...30 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 30...
Page 43: ...43 ProMinent D claration de conformite BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 43...
Page 44: ...44 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 44...
Page 57: ...57 ProMinent Declaraci n de conformidad BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 57...
Page 58: ...58 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 58...
Page 59: ...59 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 59...