11.4.14 Checking the Level Switch in the Production Tank
A1982
1.
Fig. 61: Level switch in the production tank
1.
Unscrew the coupling of the level switch and remove the
level switch.
2.
Replace the level switch during three-yearly
maintenance.
Check the two floats for dirt and damage and clean or
replace the level switch if necessary.
11.4.15 Replacing the Chlorine Gas Valve
A1983
1.
Fig. 62: Replacing the chlorine gas valve (1)
1.
Loosen the threaded connectors on the chlorine gas valve
(1).
2.
Remove the connector cap for the chlorine gas valve.
Preventative maintenance