A1719
Fig. 15: PE coupling connectors
A1720
2.
1.
3.
Fig. 16: Brine tank with hoses and coupling
1. Prepared PE coupling in the brine tank
2. Black 1.8 mm PE hose
3. White transparent 8 mm nylon hose
27. First connect the PE couplings to the system, as shown in
Fig. 14.
The PE coupling connectors are shown in Figure Fig. 15.
Ensure that the hose is inserted fully into the coupling.
A 1.8-mm PE hose (Ø16 mm) is located in the brine tank.
The PE hose (2) is black. The PE hose has a length of 5
metres.
Connect the PE hose between the "Brine storage tank filling"
connector on the system and the Ø16 mm connector (1) on
the brine tank.
Connect the 1.8 mm PE hose (2) between the "Brine mem‐
brane cell" connector on the system and the Ø16 mm con‐
nector on the brine tank.
28. Connect the transparent 8-mm nylon hose (3) between the
"Brine softener" connector on the system and the Ø10 mm
connector on the brine tank.
A white transparent 8-mm nylon hose Ø10 mm (3) is located
in the brine tank in Fig. 16.
Connect the white transparent hose to the connector on the
system.
29. Connect a Ø40 mm PVCU line to the brine tank and to the
sewerage system as an overflow line.
A1718
1.
2.
3.
Fig. 14: PE couplings for connection
to the system and brine tank
A1721
3.
1.
2.
Fig. 17: Couplings
1. "Filling brine tank" PE coupling
2. "Brine membrane cell" PE cou‐
pling
3. Coupling for transparent "Brine
softener" hose
Installation and assembly
28
Summary of Contents for Chlorinsitu-III
Page 18: ...A1706 15 4 13 3 3 16 12 17 Fig 8 Components of the system side B Components of the system 18 ...
Page 117: ...117 ...
Page 118: ...118 ...