Operation
WARNING!
Danger of electric shock
Supply voltage may be present inside the pump
housing.
– Safely and quickly disconnect the pump from
the mains/power supply if the pump housing
has been damaged.
Only return the pump to operation after an
authorised repair.
11.1 Manual operation
The instructed persons have been instructed by the operator in a
training session about the tasks allocated to them and potential
dangers arising from incorrect and improper conduct.
11.1.1 Capacity
The capacity is determined by the stroke length and the stroke
rate.
The stroke length is adjusted by the stroke length adjustment knob
within a range of 0 ... 100 %. A stroke length of between 30 ... 100
% (SEK type: 50 ... 100 %) is recommended to achieve the speci‐
fied reproducibility!
Data
Value Unit
Recommended stroke length,
standard type
30 ... 100 %
Recommended stroke length, SEK
type
50 ... 100 %
The stroke rate can be set within a range of 10 ... 100 % using the
multifunctional switch.
11.1.2 Functions
The pump has the following functions:
The pump can be remotely stopped via the "External Control" ter‐
minal. The "Pause" function only works via the "External Control"
terminal.
The pumps can be stopped by turning the multifunctional switch to
"Stop" without disconnecting it from the mains power supply.
Priming (transient conveyance at maximum frequency) can be pro‐
vided by turning the multifunctional switch to "Test".
Instructed person
"Pause" function
"Stop" function (optional)
"Priming" function
Operation