ProMinent 040830 SST Operating Instructions Manual Download Page 27

* at rated load
The contacts are potential-free.
The pacing relay is a N/O as standard.

Supply voltage for pacing relay PCB

Available supply vol‐

tages

Mains supply fre‐

quency

Power consumption

230 V AC (180-254 V) 50 / 60 Hz

10 mA (at 230 V, 50 Hz)

115 V AC (90-134 V)

50 / 60 Hz

15 mA (at 115 V, 60 Hz)

24 V DC (20-28 V)

-

10 mA (at 24 V DC)

Install the heating cartridge according to its documentation. It must

only be connected to the supplied power supply!

Install the other units in line with their documentation.

Heating cartridge

Other units

Installation, electrical

 

 

 

27

Summary of Contents for 040830 SST

Page 1: ...s P_SI_0075_SW Original operating instructions 2006 42 EC Part no 985905 BA SI 064 01 14 EN Please carefully read these operating instructions before use Do not discard The operator shall be liable fo...

Page 2: ...to the correct operation of the unit or is intended to make your work easier Safety notes Safety notes are identified by pictograms see Safety Chapter These operating instructions conform to current E...

Page 3: ...a 45 14 2 Shipping weight 46 14 3 Wetted materials 47 14 4 Ambient conditions 47 14 4 1 Ambient temperatures 47 14 4 2 Media temperatures 47 14 4 3 Air humidity 48 14 5 Motor data 48 14 6 Stroke actua...

Page 4: ...DN 32 4 with relief valve FPM seal no valve spring 5 with relief valve FPM seal with valve spring standard for DN 32 6 with relief valve EPDM seal no valve spring 7 with relief valve EPM seal with va...

Page 5: ...ge NEMA 3 No motor with B 5 size 71 DIN Degree of protection 0 IP 55 standard 1 Exe design ATEX T3 2 Exd version ATEX T4 Stroke sensor 0 No stroke sensor standard 2 Pacing relay reed relay 3 Stroke se...

Page 6: ...se the pump to meter liquid metering chemicals n In potentially explosive atmospheres in zone 1 device category II 2G explosion group II C only operate the pump with the appropriate nameplate and the...

Page 7: ...n Technical personnel service Installation electrical Electrical technician Operation Instructed person Maintenance repair Technical personnel service Decommissioning disposal Technical personnel serv...

Page 8: ...fe elec trical circuits The following information relates essentially to the unique characteristics in areas at risk from explosion but does not replace the standard operating instructions Only clean...

Page 9: ...down loads CAUTION Danger of personnel injury and material damage The use of untested third party parts can result in personnel injuries and material damage Only fit parts to metering pumps which have...

Page 10: ...e latest safety data sheet from the supplier for the chemicals resources to be used with the system The operator should create the legal framework for safe operation of the system or system component...

Page 11: ...storage or transportation The unit should only be stored or transported in a well packaged state preferably in its original packaging Only transport the unit when the red gear bleeding plug is pushed...

Page 12: ...pment and control elements S3Ba 1 Drive motor 2 Drive unit 3 Stroke length adjustment knob 4 Liquid end with relief valve 5 Diaphragm rupture sensor 1 2 P_SI_0088_SW Fig 4 Sigma control elements 1 Rel...

Page 13: ...length n 100 4 rotations n 25 1 rotation n 0 5 1 scale mark on stroke adjustment dial PG11 PG9 1 2 3 A B P_SI_0036 Fig 6 Front cover for version with pacing relay A Pacing relay cable B Supply voltag...

Page 14: ...One cycle is thus completed 4 2 1 5 3 13 Fig 7 Cross section through the liquid end 1 Suction valve 2 Diaphragm 3 Discharge valve 4 Dosing head 5 Backplate 13 Safety diaphragm 5 3 Integral relief valv...

Page 15: ...in the event of a diaphragm rup ture the lowered red cylinder 6 springs forward beneath the transparent cover 7 so that it then becomes clearly visible see Fig 9 With the electrical diaphragm rupture...

Page 16: ...te CAUTION Danger from incorrectly operated or inadequately maintained pumps Danger can arise from a poorly accessible pump due to incorrect operation and poor maintenance Ensure that the pump is acce...

Page 17: ...y too low Vibrations can disrupt the liquid end valves Secure the metering pump so that no vibrations can occur Take the dimensions m for the fastening holes from the appropriate dimensional drawings...

Page 18: ...y only be transported using stain less steel dosing heads In exceptional cases where this is not possible PTFE with carbon can be used whereby our TT_ versions are manufactured from this conducting pl...

Page 19: ...ssible operating pressure of the system CAUTION Uncontrolled flow of feed chemical Feed chemicals can leak through a stopped metering pump if there is back pressure Use an injection valve or a vacuum...

Page 20: ...and then only against impermissible positive pressure that is caused by the metering pump itself It cannot protect the system against positive pressure Protect the motor and gear of the system against...

Page 21: ...leed func tion is blocked Therefore lead the overflow line back into the storage tank When operating the integral relief valve close to the opening pressure a minimal overflow into the overflow line c...

Page 22: ...hazardous feed chemicals Hazardous feed chemical can leak out when using conventional bleeding procedures with metering pumps Install a bleed line with a return into the storage tank Shorten the retur...

Page 23: ...omponents in areas at risk from explosion Note the enclosed documentation for the individual elec trical components WARNING Danger of electric shock Unprofessional installation may lead to electric sh...

Page 24: ...ion against heating from overloading Ensure that motors are only installed and inspected by a recognisably trained skilled operative in areas at risk from explosion Observe the enclosed operating inst...

Page 25: ...tors or special motor flanges are possible on request CAUTION Provide a separate power supply for the external fan with motors with external fans identity code specification R or Z Connect up the moto...

Page 26: ...ng device and that of the stroke sensor see chapter Technical data 1 Install the cable which originates from the pacing relay see the figure in the chapter entitled Overview of equipment and control e...

Page 27: ...er consumption 230 V AC 180 254 V 50 60 Hz 10 mA at 230 V 50 Hz 115 V AC 90 134 V 50 60 Hz 15 mA at 115 V 60 Hz 24 V DC 20 28 V 10 mA at 24 V DC Install the heating cartridge according to its document...

Page 28: ...cessary flushing pipes or bleed lines have been connected CAUTION Prior to commissioning check that the power end motor and corresponding ancillary equipment is connected in compli ance with the regul...

Page 29: ...essure that is caused by the metering pump itself It cannot protect the system against positive pressure Protect the motor and gear of the system against posi tive pressure using other mechanisms Prot...

Page 30: ...can occur Only adjust the stroke length when the pump is running This is easier and also better for the pump 20 0 0 50 25 75 5 75 0 5 0 25 10 30 P_SI_0095_SW Fig 19 Adjusting the stroke length n 100...

Page 31: ...ement Only perform tests and repairs in compliance with DIN EN IEC 60079 17 and only permit experienced per sonnel who have the requisite knowledge to perform the work These measures constitute the mi...

Page 32: ...kits In case of doubt refer to the exploded views and ordering information in the appendix Interval Maintenance work Personnel After approx 5 000 oper ating hours Change gear oil refer to Changing ge...

Page 33: ...an oil trough under the oil drain plug 2 3 Unscrew the oil drain plug 2 from the power end housing 4 Allow the gear oil to run out of the power end 5 Screw in the oil drain plug 2 with a new seal Fil...

Page 34: ...pump CAUTION Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic components if they are manipulated or opened due to pressure in the liquid end and adjacent parts of...

Page 35: ...chnical personnel CAUTION Warning of personal injury and material damage Feed chemical may escape from the liquid end for example if ball valves not repaired correctly Only use new components which fi...

Page 36: ...With the pump running move the stroke adjustment dial to the stop at 0 stroke length The drive axle is now difficult to turn 3 Switch off the pump 4 Unscrew the hydraulic connectors on the discharge a...

Page 37: ...ump s fitting position 14 Tighten the screws gently to start with 15 Screw the diaphragm rupture sensor into the dosing head 16 Start up the pump and adjust the stroke length to 100 17 Stop the pump a...

Page 38: ...nsor Optical diaphragm rupture sensor 1 Unscrew the transparent cover from the diaphragm rupture sensor 2 Press the red cylinder into the diaphragm rupture sensor until it engages 3 Press the piston o...

Page 39: ...the diaphragm is damaged then feed chemical can escape when there is a dia phragm rupture The piston must not be scratched it must remain com pletely smooth so that during operation it does not damag...

Page 40: ...ith combustible media These may start to burn when combined with oxygen During filling and draining of the liquid end an expert must ensure that feed chemical does not come into con tact with oxygen W...

Page 41: ...ncy 2 Wire the motor correctly Electrician The mains voltage has failed Eliminate the cause Electrician Fluid is escaping from the back plate The dosing head screws are no longer tight enough Tighten...

Page 42: ...e dosing Once the operating membrane has ruptured precise dosing of the pump can no longer be guaranteed Do not continue to use the pump for critical process dosing For uncritical processes the pump c...

Page 43: ...y notes relating to the Storage Transport and Unpacking chapter are read before shipping or transporting the unit Thoroughly clean the liquid end and the housing of chemicals and dirt Adhere to the sa...

Page 44: ...g the feed chemical to run out 4 Flush the liquid end with a suitable medium Observe the safety data sheet Flush the dosing head thoroughly when using haz ardous feed chemicals 5 Possible additional w...

Page 45: ...08 33 7 103 5 2 1 1 2 DN25 120270 PVT 10 292 33 8 144 5 2 1 1 2 DN25 120270 SST 12 292 33 8 144 5 2 1 1 2 DN25 120330 PVT 10 365 33 8 180 5 2 1 1 2 DN25 120330 SST 12 365 33 8 180 5 2 1 1 2 DN25 07041...

Page 46: ...492 130 86 4 1 2 DN32 070410 SST 7 102 492 130 86 4 1 2 DN32 070580 PVT PPT PCT 7 102 696 183 124 4 1 2 DN32 070580 SST 7 102 696 183 124 4 1 2 DN32 040830 PVT PPT PCT 4 58 1000 264 173 3 1 2 DN32 04...

Page 47: ...Ceramic hast C CTFE PTFE PVDF FPM or EPDM SST Stainless steel 1 4581 PTFE Stainless steel 1 4404 Hast C PTFE Stainless steel FPM or EPDM Metering diaphragm is PTFE coated The valve spring is coated wi...

Page 48: ...ameplate Motor data sheets special motors special motor flanges external fan temperature monitoring For further information for the motor with identity code specification S refer to the motor data she...

Page 49: ...ing to a pro tective low voltage e g in accordance with EN 60335 1 SELV The cable can be connected as required 5 25 V DC in accordance with Namur or DIN 60947 5 6 potential free design Data Value Unit...

Page 50: ...ctive surface cov ered 1 mA Rated switching distance 1 5 mm Ri 1 k Cable colour Polarity blue brown 14 10 Relay The electrical data for the relay are contained in the chapter Installation electrical 1...

Page 51: ...umber During operation with an automatic stroke length adjustment control together with a variable speed motor the stroke rate must not fall below 30 strokes min Otherwise technical problems occur bec...

Page 52: ...4 2 500 0 1100 1000 900 800 700 600 300 400 100 200 041030 040830 070580 070410 0 20 40 60 10 30 50 80 70 90 100 300 0 500 400 100 200 120270 120190 120145 0 1 6 10 12 9 7 5 0 300 500 400 100 11 8 4 3...

Page 53: ...16 Dimensional drawings Compare the dimensions on the dimension sheet and pump All dimensions are in mm Dimensional drawings 53...

Page 54: ...Dimensional drawings 54...

Page 55: ...Dimensional drawings 55...

Page 56: ...Dimensional drawings 56...

Page 57: ...Dimensional drawings 57...

Page 58: ...145 120190 120270 120330 1 Spring 2 Ball 3 Ball seat 4 Diaphragm rupture sensor visual 1033323 5 Valve 740615 6 Multi layer diaphragm 1029604 The items listed are included in the spare parts kit Speci...

Page 59: ...Type 070410 070580 040830 041030 1 Spring 2 Ball 3 Ball seat 4 Diaphragm rupture sensor visual 1033323 5 Valve 1002806 6 Multi layer diaphragm 1029603 The items listed are included in the spare parts...

Page 60: ...0830 041030 10 Relief valve compl 10 bar PVA 1005626 10 Relief valve compl 7 bar PVA 1004801 10 Relief valve compl 4 bar PVA 1004778 The items listed are included in the spare parts kit Springs made f...

Page 61: ...70 120330 1 Spring 2 Ball 3 Ball seat 4 Diaphragm rupture sensor visual 1033323 5 Valve 803708 6 Multi layer diaphragm 1029604 The items listed are included in the spare parts kit Special accessories...

Page 62: ...tion Type 070410 070580 040830 041030 1 Spring 2 Ball 3 Ball seat 4 Diaphragm rupture sensor visual 1033323 5 Valve 1002811 6 Multi layer diaphragm 1029603 The items listed are included in the spare p...

Page 63: ...830 041030 10 Relief valve compl 12 bar SSA 1005625 10 Relief valve compl 7 bar SSA 1005042 10 Relief valve compl 4 bar SSA 1005038 The items listed are included in the spare parts kit Springs made fr...

Page 64: ...gs Spare parts kit for material ver sion Seals Part no SPK PRV 4 bar PVT SST PTFE 1031204 SPK PRV 7 bar PVT SST PTFE 1031205 SPK PRV 10 bar PVT PTFE 1031201 Scope of supply see exploded view drawings...

Page 65: ...ith 2 complete valves 1046480 Material version Liquid end Suction pressure connector Seals ball seat Balls Integral bleed valve or relief valve PVT PVDF PVDF PTFE PVDF Glass PVDF EPDM SST Stainless st...

Page 66: ...the version distributed by us This declaration loses its validity in the event of a modification to the product not agreed with us Designation of the product Metering pump Sigma product range Product...

Page 67: ...Y 1 or 2 or X 1 2 or 3 and Y A or X V and Y 2 Serial number refer to nameplate on the device Relevant EC directives EC Machinery Directive 2006 42 EC EC EMC Directive 2004 108 EC EC Explosion Preventi...

Page 68: ...986270 1 en_GB 2011 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 612 email info prominent com Internet www prominent com...