promethean Activesound One Instruction Manual Download Page 41

 

41 

Safety Instructions for 

European Countries  

Power disconnection. Unit with or without ON-OFF switches have power 
supplied to the unit whenever the power cord is inserted into the power 
source; however, the unit is operational only when the ON-OFF switch is 
in the ON position. Unplug the power cord to disconnect the main power 
for all units.   

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT 
CAREFULLY 

This appliance is supplied with a moulded three pin mains plug for your 
safety and convenience. A 13 amp (CAE-100W) and 3 amp (CAE-50W, 
CAE-20W, RC-07) fuse is fitted in this mains plug. Shall the fuse need to be 
replaced, please ensure that the replacement fuse has a rating of 13 amp 
(CAE-100W) and 3 amp (CAE-50W, CAE-20W, RC-07, BD09)and the it is 
approved by ASTA or BSI 

to 

BS1362. 

 
 
Check for the ASTA mark or the BSI mark on the body of the fuse. If the 
plug contains a removable fuse cover you must ensure that it is refitted when 
the fuse is replaced. If you lose the fuse cover, the plug must not be used 
until a replacement cover is obtained.  
 

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE 
SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE 
REMOVED AND THE PLUG CUT OFF AND DISPOSED OF 
SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL 
SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP 
SOCKET.  

If a new plug is to be fitted please observe the wiring code as shown below. 
If in any doubt, please consult a qualified electrician.  

WARNING: This apparatus must be earthed. 

IMPORTANT 

The wires in this mains lead are coloured in accordance with the following 
code: 
  Green 

and 

yellow: Earth 

 

 

Blue: 

 

 

Neutral 

 

 

Brown:   

 

Live 

As the colours of the wire in the mains lead of this appliance may not corre-
spond with the coloured markings identifying the terminals in your plug, 
proceed as follows.  
 

Summary of Contents for Activesound One

Page 1: ...Promethean Activsound One Instruction Manual...

Page 2: ...the Microphone as a Transmitter Installation About the Coaxial Cables Setting the Frequency Installing the Bracket Fuse Part Numbers Teacher s Check List Troubleshooting Special Instructions for Europ...

Page 3: ...mos bajo nuestra nica responsabilidad que el producto a que hace referencia esta declaraci n est conforme con las normas u otros docu mentos normativos siguiendo las estipulaciones de las directivas 2...

Page 4: ...Finnish Ilmoitamme yksinomaisella vastuullamme ett tuote jota t m ilmoitus koskee noudattaa seuraavia standardeja tai muita ohjeellisia asiakirjoja jotka noudattavat direktiivien 2006 95 EC ja 2004 1...

Page 5: ...o your outlet consult an elec trician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs con venience receptacles and the points whe...

Page 6: ...any servic ing other than that contained in the operating instructions unless you are qualified to do so WARNING To reduce the risk of fire or electric shock do not expose this re ceiver amplifier to...

Page 7: ...erence when the equip ment is operated in a commercial environment This equip ment generates uses and can radiate radio frequency en ergy and if not installed and used in accordance with the instructi...

Page 8: ...Frequency Explanation of Symbols The date or a dating code not exceeding any three consecutive months of manufacture The dating code shall be in an established alphanumeric code affirmed by the manuf...

Page 9: ...kaline 2 x 1 5V 2 AA rechargeable Ni MH 2 x 1 2V Battery life 6 to 8 hours Size 4 0 H x 6 0 W x 2 0 D 102 mm H x 152 mm W x 51 mm D Weight 5 6 oz 158 75g with alkaline batteries Handheld transmitter S...

Page 10: ...is used to adjust the level of the infrared microphone 4 Infrared Signal Indicator Teacher 1 and 2 Lights green when the infra red wireless receiver is receiving a signal 5 Auxiliary Input volume Cont...

Page 11: ...Input terminal TV DVD and CD MP3 Connections for TV DVD and CD MP3 9 Line output terminal Provides a line level output for connection of personal FM system recording devices or video conferencing sys...

Page 12: ...m the receiver through the coaxial cable 3 Frequency selection switch 1 2 3 4 Must be set on 1 2 Switches between 1 2 1ch and 2ch or 3 4 3ch and 4ch by changing the recep tion frequency 4 Power indica...

Page 13: ...ared sensor output provides signals from the vari ous infrared sensors Connect to the sensor input terminal of the infrared wireless receiver via F connectors and coaxial cable Operating Controls AE D...

Page 14: ...0 80 seconds on 0 16 seconds off On Charging is finished Flashing quickly Indicates an abnormality Flashing 0 16 seconds on 0 16 seconds off 8 External Auxiliary input terminal on the side Used to con...

Page 15: ...or the battery charger 7 Charging indicator The charging indicator provides a red light to indicate the following con ditions when the infrared microphone is being charged Off The correct re chargeabl...

Page 16: ...el of the infrared wireless receiver in 2 dB steps in a range of 6 dB to 16 dB Increase volume level when the switch is pressed Decrease volume level when the switch is pressed 13 Auxiliary input infr...

Page 17: ...nsert the Teardrop Microphone AERC 07 directly to charge 3 Adapter Inserted in the charging slot 2 to charge the Hand held Microphone AEH 07 Uses two Panasonic NiMH AA rechargeable batteries Use the s...

Page 18: ...lume of the system 1 Adjust the level of the appropriate infrared microphone 3 2 Adjust the level of the appropriate auxiliary input 5 to desired playback level Do not bring your ear close to the Infr...

Page 19: ...to the left to remove it For the AERC 07 pull the cover of the battery case on the back of the micro phone in the direction of the arrow to remove it 3 Insert the battery Use two NiMH batteries and b...

Page 20: ...ally for the infrared wireless microphone To charge the handheld microphone AEH 07 attach the adapter 3 and then insert the microphone Insert the Teardrop Microphone AERC 07 directly into the charger...

Page 21: ...controller selector switch Select whether to adjust the volume of your OWN microphone or the OTHER microphone by selecting OWN or OTHER on the volume con troller selector switch on the AERC 07 2 Press...

Page 22: ...nect an external device to the external input terminal Connect the portable CD or MP3 player to the external input terminal 8 with a 3 5 mini plug 2 Adjust the volume to the desired level Use the exte...

Page 23: ...ions for the RC 07 This connection diagram is an example of using 1 or 2 infrared wireless micro phones with the portable infrared amplifier With this configuration set the frequency selector switch o...

Page 24: ...EDS 07 Coaxial cable Coaxial cable For Reception in Large Areas For reception in large areas add EDS 07 sensors as shown below Up to 4 EDS 07 sensors can be added to the infrared portable amplifier Wi...

Page 25: ...d sensor as far away as possible more than 5 meters from a window In spite of installed far away more than 5 meters from the windows the effec tive range of the sensor is not improved try to install m...

Page 26: ...one and the photoreceptor sensor Install the infrared sensor as far away as possible more than 1 meter from fluorescent lighting The sensors may not operate if there is a strong source of electro magn...

Page 27: ...the ceiling panel and cut a hole about 30 mm in it and pull the cable through it 2 Attach the anchor strap Put coaxial cable through the anchor strap and tighten the adjuster 3 Install the sensor Push...

Page 28: ...installation bracket to the ceiling Attach the installation bracket to the ceiling with the screws 3 Attach the anchor strap Put coaxial cable through the anchor strap and tighten the adjuster 4 Insta...

Page 29: ...quency selector switches of the sensor and put the installation screw through the sensor and screw it into the Infrared Portable Amplifier Tighten the screw Screw tightening torque 1 18 N m 0 2 N m 12...

Page 30: ...added by using the AE DCF Installation Approximately 24 Room For one photoreceptor sensor For four photoreceptor sensors For two photoreceptor sensors Receiving from 1ch to 4ch For one set of photore...

Page 31: ...e main unit and the sensors Coaxial cable length Less than 300 Coaxial cable type RG6 When using the AE DCF sensor coupler Keep the total length of coaxial cable from the main unit to the coupler coax...

Page 32: ...Coaxial cable the length of cables B to E maximum 105 minimum 75 30 therefore there is no problem with a cable length It is within a range of 36 The cable length of A 180 C 105 285 therefore there is...

Page 33: ...ove the case of the infrared wireless microphone and set the transmission Frequency Use the frequency setting switch to select the desired transmission channel Position 1 Channel 1 2 30 MHz position 2...

Page 34: ...ge head height and doesn t disturb free movement in hallways 4 You must test the MTBR 07S Bracket before setting Infrared Portable Amplifier BD 09 5 The maximum weight allowed on the mount is 55 lbs 6...

Page 35: ...nothing is loose Do a visual check and make sure that nothing is unsteady and the screws are tight 3 Attach the wire lope on the handle then fix on the wall 35 Installing the Bracket Bracket Main unit...

Page 36: ...ce it when strength is insufficient Please secure the AC adapter as follows when it is required to be installed higher than 30 inches from the floor Use metal tie wrap and tie up two parts with someth...

Page 37: ...37 Fuse for Portable Amplifier Manufacturer Littelfuse Inc Series 218 Reference F101 Part Number 0218002 MXP...

Page 38: ...have a clear path to the receiving sensors POSITION the transmitter microphone six inches from your mouth RELAX and speak at a comfortable level Remember you do not have to project your voice CHARGE t...

Page 39: ...O Is there anything covering the transmitter YES Free the transmitter from any obstructions NO Contact Promethean NO Contact Promethean for assistance NO Have your batteries been charged overnight YES...

Page 40: ...in your room to determine if it works and contact Promethean NO Verify if a red light is showing on the dome sensor and contact Promethean NO Are your batteries fully charged YES If the batteries are...

Page 41: ...the ASTA mark or the BSI mark on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must...

Page 42: ...he terminal in the plug which marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L or coloured re...

Page 43: ...tial negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designat...

Page 44: ......

Reviews: