8.  Display structure  

 
 
By default, the UMU-FD 2 switches to monitoring mode for process monitoring. The 
UMU-FD 2 can be switched to configuration or simulation mode using the buttons on 
the front panel. 
 
 

UMU-FD 2 

Line 1 shows the scaled process va-
lue 

 

Line 2 shows the selected enginee-
ring unit 
Line 3 shows the analog output value 
or TAG number 
Line 4 shows the relay and communi-
cation status as well as the signal 
history 

 
 

8.1  Operation of the function keys  

 

When using the FD 2 front display to configure a UMU device, you are guided 
through all parameters and can select the appropriate settings for the respective ap-
plication. There is a scrolling help text for each menu, which is automatically shown 
on the 3rd line of the display. 

The configuration can be carried out using 3 function keys: 

•  With ▲ you can increase the numerical value or select the next parameter. 
•  With ▼ you can decrease the numerical value or select the previous parame-

ter. 

•  With OK you can save the selected value and continue to the next menu. 

 

After completing the configuration, the display returns to the normal state (monitor-
ing). If 3 is held down, one can return to the previous menu or to the normal state 
without saving the changed values or parameters. 
 

If no key is pressed for 1 minute, the display returns to the normal state without sav-
ing the changed values or parameters. 

 
For more information on the device-specific programming menus, please refer to the 
operating instructions for the respective device. 

 

Summary of Contents for UMU-FD 2

Page 1: ...edersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com User manual Configuration module front display UMU...

Page 2: ...Stuff qualification 7 3 3 Special hazards 7 4 Starting and operation 8 4 1 Before mounting 8 4 2 Assembly Installation Configuration 8 5 Configuration module front display UMU FD 2 8 6 Attaching detac...

Page 3: ...gible e g due to mechanical damage traceability is no longer ensured The sensors described in the operating instructions are developed and manu factured according to the latest knowledge All component...

Page 4: ...efore using the device Only qualified persons technicians are allowed to install this device If the device is not used as described in this manual the protective devices of the de vice will be impaire...

Page 5: ...n If report them immediately 2 2 Packaging Do not remove packaging until just before mounting Keep the packaging as it will provide optimum protection during transport e g change in installation site...

Page 6: ...are persons who set or operate the pushbuttons or potentiom eters of the product during normal operation and who have been made familiar with the content of this manual Reception and unpacking Unpack...

Page 7: ...l applica tions e g for hazardous media such as acetylene combustible or toxic substances as well as for refrigeration systems and compres sors Failure to comply with the relevant regulations can resu...

Page 8: ...d the technician must use tools and instruments that are safe from the point of view of safety Operation in normal mode The operating personnel may only adjust or operate the device if these are insta...

Page 9: ...Programming access can be blocked by assigning a password The password is stored in the device saved to ensure a high level of protection against unauthorized configuration changes 6 Attaching detachi...

Page 10: ...nal 7 Electrical data Environmental conditions Operating temperatur 20 C to 60 Storage temperature 20 C to 85 C Relative humidity 95 RH non cond protection class IP20 after installation Installation i...

Page 11: ...rs and can select the appropriate settings for the respective ap plication There is a scrolling help text for each menu which is automatically shown on the 3rd line of the display The configuration ca...

Page 12: ...elay energized When the icon flashes with 1 or 2 it means a delay in relay action configurable on off delay The arrow keys indicate that the process value is going up down The circle icon confirms the...

Page 13: ...messtec com 9 Settings flow chart The display will return to Monitor monitoring mode from any menu if no button is pressed for 1 minute The menus texts with a gray background are only displayed as an...

Page 14: ...use the original packaging or a suit able package To avoid a damage use for example antistatic plastic film shock absorbent material a marking as highly sensitive measuring instru ment 10 3 Liability...

Page 15: ...orrect handling of the device you should contact promesstec GmbH directly The installation and connection of the device must be carried out in accordance with the applicable regulations of the respect...

Reviews: