6.1 Factory settings
The current loop is set in such a manner that 4 mA corresponds to zero flow and
20 mA corresponds to its maximum value.
The address of the meter is set to 1 by default and communication parameters to
2400Bd, 8db, 1sb, parity EVEN (Mbus) or 9600Bd, 8db, 1sb, no parity (Modbus).
Access password (PIN) for parameter changing is always set to 0000 and this
value will be reset in case of restoring to factory default settings.
Impulse constants and current loop
– factory settings
Diameter
nominal
Impulse output
4
– 20mA (in Qmin/Qmax 1/100
range)
DN
Vout[imp/l]
Vout - pulse width
[ms]
Q[l/h] for 4mA
Q[l/h] for
20mA
6
on request
8
on request
10
10
4
0
3,400
15
10
4
0
7,600
20
10
4
0
14,200
25
10
4
0
21,000
32
1
4
0
34,000
40
1
4
0
54,000
50
1
4
0
84,000
65
1
4
0
144,000
80
1
4
0
220,000
100
0.1
4
0
340,000
125
0.1
4
0
534,000
150
0.1
4
0
760,000
200
0.1
4
0
1,350,000
300
0.1
4
0
3,052,000
400
0.1
2.5
0
5,400,000
Diameter
nominal
Resolution
V
Resolution
Q
DN≤15
V [0.001 m3]
Q [0.001 m3/h]
50≥DN>15
V [0.01 m3]
Q [0.01 m3/h]
DN>50
V [0.1 m3]
Q [0.1 m3/h]