Resistance
Range
Resolution
Accuracy
Open Circuit
Volts
200
Ω
10m
Ω
±(0.25% rdg + 10 d)
3.3Vdc
2k
Ω
0.1
Ω
±(0.15% rdg + 3 d)
3.3Vdc
20k
Ω
1
Ω
±(0.15% rdg + 3 d)
3.3Vdc
200k
Ω
10
Ω
±(0.15% rdg + 3 d)
3.3Vdc
2M
Ω
100
Ω
±(0.25% rdg + 10 d)
3.3Vdc
20M
Ω
1k
Ω
±(1.0% rdg + 10 d)
3.3Vdc
Overload Protection:
500V DC or RMS AC
Continuity Test
Range
Audible
Threshold
Response Time
Open Circuit
Volts
2V
Less than
100
Ω
Approx. 500ms
3.3Vdc typical
Overload Protection:
500VDC or RMS AC
Diode Test
Range
Resolution
Accuracy
Test
Current
Open Circuit
Volts
2V 0.1mV
±(0.5% rdg
+ 1d)
1.0mA
3.3Vdc
typical
Audible Indication:
< 0.2V
Overload Protection:
500VDC or RMS AC