ECHOES ANALYSER MODE (DVB-T / DVB-T2 / DVB-C2)
Measurement
range
Depends on the standard, carrier and guard interval.
Delay
0.1 ms to 224 ms. Typical configuration (DVB-T 8K, GI = 1/4)
Distance
0.3 km to 67.2 km. Typical configuration (DVB-T 8K, GI = 1/4)
Power range
0 dBc to –30 dBc. Typical configuration (DVB-T 8K, GI = 1/4)
Time scale
1/3 symbol period
DATALOGGER function
(Automatic measurement acquisition and storage)
Stored data
Signal type, modulation parameters, all measures available for
the detected signal type, and time stamp.
Timestamp
Date and time at each measured channel.
LTE INGRESS
Type of signal DVB-T, DVB-T2, DVB-C, DVB-C2, DVB-S and DVB-S2.
Presentation
LTE band plus quality parameters for a selected TV channel.
SAT IF TEST Function
(IF distribution network response for satellite band.)
Test
frequencies
3 selectable pilots.
ATTENUATION TEST Function
(Function to be used with RP-250 or RP-080 multiple pilot generator).
Test
frequencies
3 selectable pilots.
VIDEO & AUDIO
Format
MPEG-2 (MP@HL) (Main Profile High Level). MPEG-4 AVC H.264.
Aspect Ratio
16 / 9 or 4 / 3.
SI/PSI data
Service list and main PIDs.
HD Video
Resolution
1080, 720 and 576, progressive or interlaced.
Audio
MPEG-1, MPEG-2, HE-AAC, Dolby Digital and Dolby Digital Plus.
ANALOGUE SIGNALS MEASUREMENT
LEVEL MEASUREMENT
Measurement range
Terrestrial TV
& FM bands
15 dBµV to 130 dBµV (3,16 µV to 3,16 V).
Satellite TV
band
20 dBµV to 130 dBµV (31,6 µV to 3,16 V).
2
Using NetUpdate4 software application with a Windows PC platform.
3
Function to be used with RP-250 or RP-050 IF multiple pilot generator.
4
Function to be used with RP-250 or RP-080 multiple pilot generator.
7-56
August 2012
Summary of Contents for HD RANGER
Page 1: ...HD RANGER TV SATELLITE ANALYSER 0 MI1914...
Page 2: ......
Page 4: ......
Page 15: ...2 3 Equipment Details Front View Figure 4 August 2012 2 7...
Page 16: ...Lateral view Figure 5 Top view Figure 6 Optical Option 2 8 August 2012...
Page 19: ...2 6 Menu Tree SPECTRUM ANALYSER MENU TV MENU August 2012 2 11...
Page 20: ...MEASUREMENT MENU SETTINGS MENU 2 12 August 2012...
Page 21: ...INSTALLATIONS MANAGEMENT PREFERENCES MENU Figure 7 August 2012 2 13...
Page 76: ...8 68 August 2012...
Page 91: ......
Page 92: ......