11
2.4 Check Air Cleaner
Checking the air cleaner of Silent Type Diesel Generator.
Unscrew the bolt and remove side plate
(A)
(B)
•
To get the filter element, loosen the clip and remove the cover.
•
Do not clean the air cleaner element with detergent because it
is a wet type element.
•
When exhaust fume is black change the filter element.
•
Do not start the generator without the air cleaner, otherwise it
will cause the generator deteriorate easily.
•
After installing the filter element, fit the cover of air cleaner and
retighten the clipper firmly.