AIR FILTER CLEANING

1. Unscrew the air filter cover.

2. Remove filter element and wash well in solvent.

3. Pour a small amount of oil onto the filter

element and gently squeeze out any excess

oil.

4. Replace the filter element and air filter cover.

5. Be sure the filter cover seals properly all

around.

FUEL VALVE FILTER CLEANING

1. Remove the cup at the bottom of the fuel

valve with a small wrench.

2. Remove the fuel valve filter.

3. Clean and wash out the filter and cup and

replace.

FUEL STRAINER CLEANING

1. Remove the plastic fuel strainer, located below   

the fuel tank cap.

2. Wash the strainer in solvent and replace.

EXCITING THE GENERATOR:

If there is a loss of residual magnetism (voltage will 

not build up), it may be necessary to re-excite the 

unit.

NOTE: Your generator is a brushless unit. Please 

contact your local service center or the Power

tech

 

Asia

Pacific Inc.,

 Service Department for 

assistance with exciting your generator.

HEAT SHIELD:

Inspect to ensure that all heat shields and heat 

deflectors are intact and in place. Do not remove 

any parts or modify parts. Removing or modifying 

parts could cause serious damage to the unit.

ENGINE: Carburetor Icing

During the winter months, rare atmospheric 

conditions may develop which will cause an icing 

condition in the carburetor. If this develops, the 

engine may run rough, loose power, and may stall. 

Call Product Service for more information.

QUICK STARTING TIPS FOR UNITS THAT HAVE 

BEEN SITTING FOR AWHILE:

If your unit has been sitting around for a long time 

period and is hard to start, try doing some of these 

easy steps before calling the Customer Hotline.

1. Check the oil level.

2. Replace the old fuel.

3. Change the spark plug.

4. Check the fuel lines. Make sure the fuel valve

is open.

5. Check all generator parts for integrity.

6. Clean the Carburetor.

SERVICE AND STORAGE

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may 

result. to eliminate hard starting, run the generator 

at least 30 minutes every month. Also, if the unit 

will not be used for some time, it is a good idea to 

drain the fuel from the carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or 

is being stored more than one month, follow these 

instructions:

1. Replenish engine oil to upper level.

2. Drain gasoline from fuel tank, fuel line and

carburetor.

3. Pour about one teaspoon of engine oil through

the spark plug hole, pull the recoil starter    

several times and replace the plug. Then pull

the starter until you feel the piston is on its   

compression stroke and leave it in that

position. This closes both the intake and

exhaust valves to prevent the inside of the

cylinder from rusting.

4. Cover the unit and store in a clean, dry place   

that is well ventilated away from open flame

or sparks.

NOTE: We recommend always using a fuel 

stabilizer. A fuel stabilizer will minimize the 

formulation of fuel gum deposits during storage. 

The fuel stabilizer can be added to the gasoline in 

the fuel tank, or into the gasoline in a storage 

container.

10

Summary of Contents for PH1500

Page 1: ...pment thoroughly read and understand these instructions and any additional instructions provided prior to operation Record the model and serial numbers of your Generator below Model No _________________________________________ Serial No _________________________________________ PH1500 ...

Page 2: ...PH1500 ...

Page 3: ... generator clean and free of oil mud and other foreign matter 10 Extension cords power cords and all electrical equipment must be in good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator 12 Your generator should never be operated under these conditions ...

Page 4: ...be caught in the starter or other rotating parts 17 Unit must reach operating speed before electrical loads are connected Disconnect loads before turning off engine 18 To prevent surging that may possibly damage equipment do not allow engine to run out of fuel when electrical loads are applied 19 When powering solid state equipment a Power Line Conditioner should be used to avoid possible damage t...

Page 5: ... television set is used A power line conditioner is recommended for some solid state applications A power line conditioner should be used when running one or more of the following solid state items Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment Other solid state equipment may require a power line c...

Page 6: ...ying combustible material as the ground source LUBRICATION DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil Your generator has been shipped from the factory without oil in the crankcase Operating the unit without oil can damage the engine Fill the engine with oil according to the operator manual For units with a dipstick fill oil to the prop...

Page 7: ... to bring the level back up to the manufacturer s required level WARNING Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging Connect the red clip to the position terminal of the battery Connect the black clip to the negative terminal of the battery Insert the DC plug into the DC receptacle ...

Page 8: ...apacity When starting the generator disconnect all load Apply load only after generator is running Voltage is regulated via the engine speed adjusted at the factory for correct output Readjusting will void warranty When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle CIRCUIT BR...

Page 9: ... Next set the gap at 028 031 inches 0 7 0 8 mm by adjusting the negative electrode Replace the spark plug with correct torque 14 ft lb 20 N m Replace with only the same type of spark plug which was removed An improper spark plug can cause the engine to overheat emit smoke or otherwise perform poorly OIL TYPE Use new good quality oil SE SF or SD grade The oil to be used depends upon the temperature...

Page 10: ...IPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE If your unit has been sitting around for a long time period and is hard to start try doing some of these easy steps before calling the Customer Hotline 1 Check the oil level 2 Replace the old fuel 3 Change the spark plug 4 Check the fuel lines Make sure the fuel valve is open 5 Check all generator parts for integrity 6 Clean the Carburetor SERVICE AN...

Page 11: ...ope sharply No fuel in tank Fuel shut off not open Supply fuel Spark plug dirty with carbon or wet with fuel Remove carbon or wipe spark plug with dry cloth Improper spark Damage spark plug Replace plug Faulty magneto Consult dealer Combustion chamber supplied with fuel Sufficient compression Improper adjustment of carburetor Proper spark Insufficient pulling speed for starting rope Pull rope shar...

Page 12: ...osion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the product or for any costs or labor performed without the Company s pr...

Page 13: ...ly Ball bearing 6203 Stator assembly Wire clip Flat washer 5 Spring washer 5 Screw M5 15 Stator cover Rear frame Spring washer 6 Screw M6 105 Alternator center screw Alternator rear cover Nut M8 Screw M8 30 Electrical machinery rack 2 1 1 2 1 1 22 2 2 1 2 4 4 1 1 1 1 1 1 9 1 2 1 4 1 1 1 1 3 3 3 1 1 5 4 1 1 16 2 1 Ref No Part No Description Qty Note 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 5...

Reviews: