en
operating manual – Fog and smoke gas simulator
B -
4
07. Troubleshooting
Faults
Possible Causes
The FS 100 fails to
produce fog.
Check power supply and
make sure that the device is
properly connected.
Check the filling level of the
fog fluid.
Check to make sure that the
canister is leak tight.
Check the Sinter filter for
contamination.
The device makes
loud humming
noises when fog is
being produced.
The pump is running dry.
Please avoid at all costs!
Fill up with fog fluid.
Check hose connections
and make sure that they are
locked in place.
08. Technical Details
Dimensions (LxWxH)
560 x 295 x 350 mm
Weight (incl. 5 l fluid)
21,5 kg
Supply voltage
230 V / 50 Hz
Compressor output power
1.200 W
Fan turbine output power
1.200 W
Input power max
2.400 W
IP-rating
IP44
Air flow rate
approx. 50 l/s
Fluid amount in canister
5 l
Fluid consumption at max.
throughput
120 ml/min
Permanent fog
35 ml/min
Fog time at Setting 10
approx. 40 s
Setting 5 and lower
permanent fog
Warm-up time
approx. 7 min
09. Certificate of Non-Objection
Certificate of non-objection for the fog fluid “Fog
Fluid FS 100”
This is to certify that our fog fluid FL-FS 100 does not
present a hazardous working material in accordance
with §§ 3/3a Chemical Law of 16.09.1980, with mo-
difications made on 14.03.1990, Text Edition of BGBl.
(German Civil Code), 1/1990, page 522. (The modifi-
cation of Annex 1 of 05.06.1991, BGBl. 1, page 1219,
is incorporated.)
These components are not listed in the List of Main
Substances as stated in the Version of Annex VI of
the Ordinance for Hazardous Substances (Date:
26.08.1986, BGBl 1, page 1470, in the version of the
third legal ordinance for modifications of the Ordi-
nance for Hazardous Substances of 05.06.1991, BGBl.
1, page 1218). It was not assigned an MPC-value
(Maximum Permissible Concentration) according to
the IRGS 900 (Regulations for Dangerous Materials) of
the Ordinance for Hazardous Substances (MPC-Value
List 1991). It does not present a health hazard when
used properly and for the purpose for which it was
intended. The fluid is not flammable according to the
Ordinance for Hazardous Substances Part 4, Chapter
4.1. The product is water soluble and bio-degradable.