12
1. The first setting will be
Total Vacuum Time
. Using the
Plus/Minus
keys set the
total time you want the vacuum cycle to last.
2. Press the
Right Arrow
key to move to the next setting. The VAC LED will
remain on. However you are now setting the
Vacuum On Time.
3. Using the
Plus/Minus
keys set the amount of time you want each vacuum pulse to
last.
4. Press the
Right Arrow
key to move to the next setting.
5. Using the
Plus/Minus
keys set the amount of time you want the vacuum to remain
off between each vacuum pulse.
6. You have now completed setting for a Pulsed Vacuum.
7. Press the
Right Arrow
key to move to your next setting.
E
. Multi Stage Vacuum / Gas:
This function allows your machine to perform multiple
vacuum and gas stages before moving onto the seal mode. Up to 10 vacuum / gas or gas /
vacuum stages may be set.
1. With the machine in the normal operation mode Press the Purge key indicated in
Figure 6. You will see a decimal point appear in the
Program Display.
The
machine can now be set for multi-stage operations that begin with a Vacuum
cycle. If you Press the Purge key once more the decimal point will begin to blink.
The machine will now perform multi-stage functions beginning with Gas.
Note:
The vacuum will engage for 2 seconds to hold the lid down before the first
gas stage begins.
2. Once you have engaged the Purge function then enter EDIT MODE (follow the
instructions indicated in point D on page 00).
3. The
VAC LED
will be lit and you will see a number appear in the
Time /
Percentage
display. This number indicates how many stages you wish to execute.
4. Press the
Plus / Minus
keys to set the number of stages you want.
5. Press the
Left Arrow
key. You will see that the LED above the word
VAC
stays
on.
6
.
Press the
Plus / Minus
Key to set the amount of Vacuum time for all of the
vacuum stages.
This second setting is ALWAYS the vacuum time.
7. Press the
Left arrow
key. You will see that the LED above the work
VAC
remains on.
8. Using the
Plus / Minus
keys set the amount of Gas time for all gas cycles. Note:
This third setting is always the Gas time
.
Note: If you Press the Purge key a third time the decimal point will disappear.
The Purge function is now OFF and your regular Vacuum & Gas settings will
resume.
Summary of Contents for Promax DC-860
Page 19: ...16 ...
Page 23: ...20 5 3 PNEUMATIC DIAGRAM ...
Page 24: ...21 5 4 ELECTRICAL DIAGRAM FB ...
Page 25: ...22 5 4 ELECTRICAL DIAGRAM TB ...
Page 27: ...6 1 BODY 24 DC86100000 Body Diagram ...
Page 29: ...6 2 WORKING BED BOTTOM 26 C C Working bed Bottom Diagram DC86200000 ...
Page 32: ...6 3 1 CUSHION BAR FB 29 D88K2FB000 Cushion Bar Diagram ...
Page 34: ...6 3 2 CUSHION BAR FBG 31 D88K2FBG00 Cushion Bar Diagram ...
Page 36: ...6 3 3 CUSHION BAR FBPK 33 D88K2PK000 Cushion Bar Diagram ...
Page 38: ...6 3 4 CUSHION BAR FBPKG 35 D88K2PKG00 Cushion Bar Diagram ...
Page 40: ...6 3 5 SEALING BAR BOTTOM FBTB 37 DC862TB000 Sealing Bar Bottom Diagram ...
Page 42: ...6 3 6 SEALING BAR BOTTOM FBTBG 39 DC862TBG00 Sealing Bar Bottom Diagram ...
Page 44: ...6 3 7 SEALING BAR BOTTOM FBTBPK 41 D88K2TK000 Sealing Bar Bottom Diagram ...
Page 46: ...6 3 8 SEALING BAR BOTTOM FBTBPKG 43 D88K2TKG00 Sealing Bar Bottom Diagram ...
Page 48: ...6 4 CHAMBER LID DIAGRAM 45 Chamber Lid Top Diagram D88K300000 ...
Page 50: ...6 5 1 SEALING BAR TOP FB 47 D88K312A00 Sealing Bar Top Diagram ...
Page 53: ...6 5 2 SEALING BAR TOP PK 50 D88K350A00 Sealing bar Top Diagram ...
Page 56: ...53 6 6 1 ELECTRICAL BOX FB 6 6 2 ELECTRICAL BOX TB ...