background image

DOUGHPRO

SL1266 Split Lid Grill Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Parts List Ref. #

Either Heater Platen is not Heating 
but the Digital Controller is on and 
appears to be functioning.

If the Mechanical Relay (s) on the coil 
side are receiving 12vdc  indicates the 
Controller is functioning properly.  On 
the switching side of the relay, is the 
rated voltage for the Model(120,208, 
or 220~AC) going to the heater in 
question?  If there is no voltage on 
the to the switching side of the relay 
to the heaters, the Relay is not 
working properly  

 Replace Mechanical Relay. 

# 15

Heater Platen overheating

The mechanical Relay may be stuck in 
the closed position (zone 1, Lower 
Platen #1 labeled on this relay, zone 
2, left upper and zone 3, right upper).

Replace Mechanical Relay.

# 15

If  you are receiving 12vdc on the coil 
of the relay, the Controller is properly 
functioning thus maybe you have a 
break in the wire to the heater (s) or 
the Heater Platen lost it's continuity

One of the Heater's embedded into 
to the Heated Aluminum Platen may 
have lost Continuity.  With use of a 
Ohm Meter a condinuity check must 
check at the cold pins of the heater 
(where the heater wire is brazed at 
the cold pin.  This will eliminate any 
other failue before the the heater 
element validating the loss off 
condinuity at the source (Heater 
Element).  If so, either the Upper left 
(zone 2), right (zone 3) or Lower, 

#15

Either Upper Heater not coming 
down parallel to the Lower Heater 
Platen.

Parallel Lever not attached either in 
the rear out on the Upper Heater 
Platen.  Check to see if Parallel leveler 
is connected on both sides. The 
retaining clip attached to pin may 
have come off.

Reconnect the pin and the retaining  
E-Clip.

# 25

Upper Platen falling down or lost It's 
retension .

Possibly the Springs (2, one for each 
Upper Heater Platen has lost some 
retension.

Remove rear panel and adjust the 
retaining collars on shaft by winding 
spring tighter.  There are mutlple set 
screws that need to be loosened in 
order to wind the spring tighter.  
Once achieving proper tension be 
sure to tighten all set screws so that 
tension isn't lost again.

___

If one heating zone is not reaching 
setpoint and another heater is 
overheating

Sensors maybe crossed

Make sure each sensor is connected 
to it's prospective postion on the 
terminal block which in turn to the 
Controller.

___

Summary of Contents for ProGrill Taco Bell SL1266TB

Page 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com 266 revC 101416 rev8 71713 ...

Page 2: ...n the power switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the display stops flashing and beeps 3 times Step 4 Operation Simply place product on either side of the grill close lid and press the desired pre set time cycle 10 or 20 seconds After the time cycle is ...

Page 3: ...t is turned on All preset LED s are turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the display starts flashing until the clean set point is reached To stop the clean cycle simply press the CLEAN button once to deactivate the clean cycle The CLEAN LED is turned off the preset LED s are restor...

Page 4: ...ILQG WKH WHPSHUDWXUH RI WKH 2 5 3 7 16 3UHVV WKH 7 03 5 785 EXWWRQ DQG WKH 552 2 1 EXWWRQ DW WKH VDPH WLPH 275 is the factory default temp for the CLEAN cycle To change the CLEAN cycle temp simultaneously hold down the TEMP and CLEAN buttons for 15 seconds The current temp setting will display on the right digital display only Using the up or down arrows to adjust to the desired temp 275 is the fa...

Page 5: ...17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 By QVWUXFWLRQ V IRU GMXVWLQJ WKH 7HPSHUDWXUH 35 66 DQG KROG WKH 7 03 DQG 552 XS EXWWRQV VLPXOWDQHRXVO IRU VHFRQGV 7KH FXUUHQW WHPSHUDWXUH VHWWLQJ ZLOO GLVSOD RQ WKH ULJKW GLJLWDO GLVSOD R...

Page 6: ...t Upper Platen has the open sensor or probe same goes for the down arrow indicating Lower Platen Sensor in one of two zones lost it s continuity Depress Temp While depressing Temp depress either up or down arrow to locate error message PROB zone 1 Lower Platen zone 2 Left Upper Platen zone 3 right Upper Platen If occurred when depressing the up arrow indicates either the left or right Upper Platen...

Page 7: ...With use of a Ohm Meter a condinuity check must check at the cold pins of the heater where the heater wire is brazed at the cold pin This will eliminate any other failue before the the heater element validating the loss off condinuity at the source Heater Element If so either the Upper left zone 2 right zone 3 or Lower 15 Either Upper Heater not coming down parallel to the Lower Heater Platen Para...

Page 8: ...6 2X 16 2X 42 4X 47 4X 62 4X 24 2X 21 23 8 52 4X 28 14 51 2X 43 2X 65 2X 63 2X 75 4X 6 77 40 SL1266TBA EXPSL1266TBA RE 012819 CUSTOMER MANUAL SHEET 1 OF 3 64 6X 46 6X 31 50 6X 73 6X A7 LOWER PLATEN ASSY REFERENCE SHEET 2 LEFT UPPER PLATEN ASSY REFERENCE SHEET 3 RIGHT UPPER PLATEN ASSY REFERENCE SHEET 3 15 2X 29 A ...

Page 9: ...DETAIL B EXPSL1266TBA RE 012819 CUSTOMER MANUAL SHEET 2 OF 3 35 2X 33 2X 36 3X 27 3X 32 34 39 30 67 3X 44 3X 41 6X 58 55 56 10X 57 2X DETAIL A B 66 4X 49 4X 48 12X 7 2 37 53 4X A5 A6 ...

Page 10: ...52 4X 10 1 61 3X 47 3X 45 3X 19 68 2X A1 38 A3 EXPSL1266TBA RE 012819 CUSTOMER MANUAL SHEET 3 OF 3 52 4X 11 1 61 3X 47 3X 45 3X 68 2X 20 38 A2 A4 79 ...

Page 11: ... 1 21 HANDLE LEFT ASSEMBLY 11018344027 1 22 HANDLE RIGHT ASSEMBLY 11018344026 1 23 GREASE TRAY ASSY 11018344005 1 24 PIN PIVOT FRONT 11017088865 2 25 TOP LINK 11018344017 2 26 SPACER LINK 11018344024 2 27 SINK HEAT ALUMINUM SSR 11057322 3 28 WIRE HARNESS 11018344050 1 29 OVERLAY SL1266 TACO BELL OSL1266TBB 1 30 TRANSFORMER INSULATION 1101159180 1 31 DIGITAL CONTROL 3 ZONE SOFTWARE REV 5 54 1101041...

Page 12: ...6 NUT HEX 3 8 16 NH3816 4 67 NUT HEX 8 32 NH832 3 68 BUSHING TEFLON 3 4 ID X 7 8 OD X 1 L 110115541 4 69 BUSHING FLANGED TEFLON 3 4 ID X 875 OD X 5 L 110115563 4 70 BUSHING TEFLON 3 4 ID X 7 8 OD X 3 4 L 110113441 2 71 SPRING DETENT 110115555 2 72 LOW CLEARENCE CLIP LCC3478 4 73 NYLON SPACER 1 4 X 141 X 9 32 11090109 6 74 HANDLE GRIP 110901168 2 75 FEET RUBBER 3 4 11016546469 4 76 RETAINING RING 1...

Page 13: ......

Page 14: ...air or replacement will be at the expense of Proluxe on under the normal one year warranty WHAT WE WILL DO Contact our Factory to obtain warranty service Proluxe must issue a return authorization number and call tag or find the name and location of a Factory Authorized Service Center nearest you When calling for service please furnish the model number serial number and a description of the problem...

Page 15: ...mpany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item available at that time All merchandise must be shipped freight prepaid by customer or service agency Subject to the inspection of the product by the company a restocking charge of 20 of the Net purchas...

Reviews: