background image

55

2X

2X

54

2X

2X

2

1

28

4X 42

4X

40

71

70

4X

3

75

16X

6

52

4X

76

78

74 2X

73 2X

46

45

2X

A2P

79

CSD1515

A2

2X

89

A1

73

A1P

EXPCSD1515 RC 061317 CUSTOMER MANUAL

SHEET 1 OF 2

Summary of Contents for CSD1515

Page 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model CSD1515 Digitally Controlled Clam Shell Grill ...

Page 2: ...ower switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the display stops flashing and beeps 3 times Step 4 Operation Simply place product on grill close lid and press the desired pre set time cycle ex 10 seconds After the time cycle is finished press it again to re...

Page 3: ...turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the display starts flashing until the clean set point is reached To stop the clean cycle simply press the CLEAN button once to deactivate the clean cycle The CLEAN LED is turned off the preset LED s are restored the temperature set point is chan...

Page 4: ...To find the temperature of the UPPER PLATEN Press the TEMPERATURE button and the ARROW UP button at the same time 2 To find the temperature of the LOWER PLATEN Press the TEMPERATURE button and the ARROW DOWN button at the same time 275 is the factory default temp for the CLEAN cycle To change the CLEAN cycle temp simultaneously hold down the TEMP and CLEAN buttons for 15 seconds The current temp s...

Page 5: ...tton and continue to hold both for 5 seconds The digital displays will now read their preset times as shown here Each side is capable of having up to 4 different settings making a total of 8 set times Now using the ARROW buttons you can set your desired time Once you have set the desired time simply press the TEMP button the unit will display the new set time IMPORTANT NOTE When adjusting the time...

Page 6: ...55 2X 2X 54 2X 2X 2 1 28 4X 42 4X 40 71 70 4X 3 75 16X 6 52 4X 76 78 74 2X 73 2X 46 45 2X A2P 79 CSD1515 A2 2X 89 A1 73 A1P EXPCSD1515 RC 061317 CUSTOMER MANUAL SHEET 1 OF 2 ...

Page 7: ... 4X 64 4X 72 3X 68 69 10 30 85 8X 65 10 3X 13 2X 9 4X 4 35 34 39 2X 48 2X 17 2X 37 19 44 18 2X 87 63 3X 80 3X 17 77 3X 36 4X 41 32 49 2X 15 12X 24 2X 26 23 2X 25 29 2X 58 61 27 59 61 60 59 61 59 60 4X 10 2X 38 47 4X 31 4X 62 50 11 53 2X 43 12 57 2X 7 67 56 8 EXPCSD1515 RC 061317 CUSTOMER MANUAL SHEET 2 OF 2 A4P A4 A5 A6 CSD1515 2X 88 2X 90 2X 84 2X A3 84 A3P ...

Page 8: ...4 11016546469 11016546469 11016546469 4 29 BUSHING TEFLON 3 4 LONG 110113441 110113441 110113441 2 30 GREASE TRAY 110115505 110115505 110115505 1 31 NUT HEX 6 32 NH632 NH632 NH632 8 32 TOP LINK 110115508 110115508 110115508 2 33 WIRE HARNESS CSD1515R 11018636050 11018636050 11018636050 1 34 UPPER LEVELING BRACKET 110115510 110115510 110115510 2 35 UPPERLEVELING SHIM 110115557 110115557 110115557 2...

Page 9: ...SSH5161834 SSH5161834 6 81 RTD TOP SENSOR 1108881101 1108881101 1108881101 1 82 SCREW PAN HEAD PHILLIPS 10 24 X 3 8 STAINLESS STEEL SP102438S SP102438S SP102438S 6 83 UPPER SHROUD 110121721 110121721 110121721 1 84 SCREW PAN HEAD PHILLIPS 8 32 x 3 8 SP83238 SP83238 SP83238 4 85 INSULATION UPPER PLATEN 110888251 110888251 110888251 2 86 CLEVIS ASSEMBLY LEFT HAND 110115503 110115503 110115503 1 87 C...

Page 10: ......

Page 11: ...mpany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item available at that time All merchandise must be shipped freight prepaid by customer or service agency Subject to the inspection of the product by the company a restocking charge of 20 of the Net purchas...

Reviews: