GREAT BRITAIN • CUSTOMER SERVICE
tel: 0845 300 9799, e-mail: [email protected]
INTERNET
www.clasohlson.co.uk
Ver. 20140331
Temperature Sensor for 36-5087
Art.no 36-5123
Model TW007
Please read the entire instruction manual before using the product and save it for future
reference. We reserve the right for any errors in text or images and any necessary changes
made to technical data. If you have any questions regarding technical problems please
contact our Customer Services.
Important details:
• Other wireless equipment using the same frequency can reduce the transmission range.
• The range of all wireless equipment depends on the type of obstacles located between
the transmitter and the receiver (e.g. a concrete wall will interfere with the signal more
than a plasterboard wall).
If you experience problems, try the following:
• Turn off any existing wireless equipment to see if that could be causing the problem.
• Move the wireless equipment and/or shorten the distance and reduce the number of
obstacles (walls, furniture, etc) between the transmitter and receiver.
Initialization
1. Hold in [ CHANNEL ] on the main unit until all the temperature and humidity values show “- -”.
The main unit will scan for a signal from sensors 1 and 2.
2. Open the battery cover on the back of the sensor by sliding it in the direction of the arrow.
3. Insert 2 × AAA/LR03 batteries. Note the polarity markings at the bottom of the battery
compartment to ensure correct insertion.
4. Refit the battery cover.
5. The readings from sensor 2 will appear on the display after a few seconds.
Installation
Note:
Move the sensor to its intended location and make sure that it has contact with
the main unit before permanently installing it.
• Mount the sensor upright (not lying flat or on its side) on a horizontal surface or
on a wall using the included holder.
• Make sure that the sensor is shielded from direct sunlight and heavy rain.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local authority.
Specifications
Size
40 × 80 × 20 mm
Weight
60 g
Range
Up to 100 m
Measurement range
Temperature: -20 to +70 °C (-4 to 158 ºF), accuracy ± 2.5 °C (± 4.5 ºF)
Humidity: 20–95% RH, accuracy ± 8% RH
Battery
2 × AAA/LR03
Frequency
433 MHz