Proliphix Internet Managed Thermostat (IMT) Installation Guide, Release 1.0

Part No. 600-03100-000, Rev. 2

Installing and Wiring the Thermostat

3

Remove the base plate from the wall and drill two or three holes at the marked 
locations: for drywall, drill 3/16” holes; for plaster, drill 7/32” holes.

4

Gently tap the wall anchors (included in the packaging) into the drilled holes until 
they are flush with the wall.

5

Pull the wires through the base plate and position the base plate over the screw holes. 

6

Attach the base plate to the wall using three 1" screws (included in the packaging).

Wiring the Base Plate Terminals

This section describes how to wire the base plate terminals. Use the instructions in this 
section and refer to:

„

Table 2

 and 

Figure 1 on page 5

 to wire the IMT base plate terminals for Fuel 

Burner HVAC. A Fuel Burner typically burns fossil fuel like oil or gas and does 
not have a wire used as a reversing valve.

„

Table 2

 and 

Figure 2 on page 6

 to wire the IMT base plate terminals for Heat 

Pump HVAC. A Heat Pump configuration always has a wire used to control a 
reversing valve. 

Refer to the labels you placed on the wires when you removed the existing thermostat. 
See 

page 1

.

Table 2

 lists the standard HVAC terminal label required to support the single-stage 

and dual-stage Fuel Burner and Heat Pump applications.

Note

H

Some newer Heat Pumps use traditional Fuel Burner wiring schemes without a 
Reversing Valve (RV). Therefore, you may have to use a Fuel Burner wiring 
scheme to control your Heat Pump. Refer to your Heat Pump manual for wiring 
details.

You must know the type of Reversing Valve in your heat pump. Refer to your Heat 
Pump manual for more information. 

Table 2 Terminal Conversion Chart

HVAC 
Terminal

Single Stage 
Fuel Burner

Dual Stage 
Fuel Burner

Single Stage 
Heat Pump

Dual Stage
Heat Pump

C

a

24VAC common

24VAC common

24VAC common

24VAC common

RH

24VAC hot

24VAC hot

24VAC hot

24VAC hot

RC

24VAC hot

24VAC hot

24VAC hot

24VAC hot

W1

Heat

1st stage Heat

Auxiliary Heat

Auxiliary Heat

W2

b

not used

2nd stage Heat

RVS O/B

RVS O/B

Y1

c

Cool

1st stage Cool

1st stage 
Compressor

1st stage 
Compressor

Y2

d

not used

2nd stage Cool

not used

2nd stage 
Compressor

Summary of Contents for IMT

Page 1: ...Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 2 June 2010...

Page 2: ...r of cracked scratched broken or modified plastics other cosmetic damage or parts that have been altered defaced or removed or the scratching cracking or breakage of the product This warranty is not t...

Page 3: ...ly marked on the outside of the package Products received without an RMA number or without shipping prepaid will be subject to refusal by Proliphix Proliphix reserves the right to charge a 15 restocki...

Page 4: ...iv Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 2...

Page 5: ...ecific features that are important to note during the installation Installing the Thermostat This section describes the required tools guidelines and installation instructions for the IMT Required Too...

Page 6: ...ing an unheated room or in a draft from a stairwell door or window in a corner or alcove or behind an open door Install the unit after all construction work and painting is complete Install the unit i...

Page 7: ...describes a two step installation process in which you install or mount the thermostat base plate and wire the thermostat Inserting the Battery Insert the battery that is shipped with the thermostat...

Page 8: ...ate terminals for Heat Pump HVAC A Heat Pump configuration always has a wire used to control a reversing valve Refer to the labels you placed on the wires when you removed the existing thermostat See...

Page 9: ...is either activate for heat B terminal or activate for cool O terminal You can program this function on the relay output through the web interface and the LCD screens Consult your HVAC installer about...

Page 10: ...eat cool connecting to an IMT base plate Figure 2 Dual Stage Heat Pump HVAC Connections Note The second compressor wire is not present in a single stage heat pump Common Fan Reverse for Heat Cool Dual...

Page 11: ...t the wire labeled W1 to the W1 terminal post 4 Loosen the terminal post screw used to secure the wires Insert the wire straight down into the square hole and secure the corresponding screw to the wir...

Page 12: ...4 and match the label number to the Proliphix base plate number for CAT5 CAT5E CAT6 color coding Note Only one sensor can be connected to each port Table 3 Remote Sensor Switch Settings Remote Sensor...

Page 13: ...Auxiliary Relay and Sensors Table 5 describes the Auxiliary Relay connectors Table 4 T568A and T568B Pinout Assignments Pin Number T568A Wire Color T568B Wire Color 1 Green White Orange White 2 Green...

Page 14: ...igure the Auxiliary Relay jumpers Auxiliary Relay 1 and 2 can be configured independently from each other Figure 5 Auxiliary Relays with Jumpers When the jumpers are removed see Figure 6 the Auxiliary...

Page 15: ...2 Y1 Y2 G Fuel Burner Heat1 1h X Xa a If fan on heat is enabled Heat2 2h X X Xa Cool1 1c X X Cool2 2c X X X Fan X Heat Pump Heat1 1h Xb b If Heat Pump is a model which activates the reversing valve B...

Page 16: ...source RH or RC is configured to turn on each HVAC system cool heat and fan Most applications use only RH power The Proliphix thermostat is shipped from the factory with the RH and RC jumpered togeth...

Page 17: ...ower to either two EPA 20 or six EPA 60 Proliphix Network Thermostats IMT550c and IMT550w 24VAC is power from the HVAC system which requires RH and C to both be connected to provide power to the therm...

Page 18: ...et to either Auto or Heat 2 Continuously press the Up arrow until the heat set point is higher than the temperature reading A flame icon appears and the HVAC system activates the heat Testing the Cool...

Reviews: