6. Specifications 

Tower UPS 

MODEL 

1K 

2K 

3K 

CAPACITY* 

1000 VA / 800 W 

2000 VA / 1600 W 

3000 VA / 2400 W 

INPUT 

Voltage 

Range 

Low Line Transfer 

85VAC/75VAC/65VAC/55VAC±5% or 160VAC/140VAC/120VAC/110VAC±5%   

(Ambient Temp.<35

0

C) 

( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)   

Low Line Comeback 

95VAC/85VAC/75VAC/65VAC or 175VAC/155VAC/135VAC/125VAC ± 5 %   

(Ambient Temp.<35

0

C) 

( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)   

High Line Transfer 

145 VAC ± 5 % or 300 VAC ± 5 %   

High Line Comeback 

140 VAC ± 5 % or 290 VAC ± 5 %   

Frequency Range 

40Hz ~ 70 Hz 

Phase 

Single phase with ground 

Power Factor 

 0.99 @ nominal voltage (input voltage) 

OUTPUT 

Output voltage 

100/110/115/120/127VAC or 200/208/220/230/240VAC 

AC Voltage Regulation   

±1% (Batt. Mode) 

Frequency Range   

47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range) 

Frequency Range (Batt. Mode) 

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 

Overload 

Ambient Temp.<35

0

105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when 

the utility is normal 

110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the 

utility is normal 

>130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the 

utility is normal 

Current Crest Ratio 

3:1 

Harmonic Distortion 

  3 % THD (linear load); 

  6 % THD (non-linear load) 

Transfer 

Time 

AC Mode to Batt. Mode 

Zero 

Inverter to Bypass 

4 ms (Typical) 

Waveform (Batt. Mode) 

Pure Sinewave 

EFFICIENCY 

AC Mode 

88% 

89% 

90% 

Battery Mode 

83% 

87% 

88% 

BATTERY 

Standard 

Model 

Battery Type 

12 V / 9 AH 

12 V / 9 AH 

12 V / 9 AH 

Numbers 

Recharge Time 

4 hours recover to 90% capacity (Typical) 

Charging Current   

1.0 A (max.) 

Charging Voltage   

27.4 VDC ± 1% 

54.7 VDC ±1% 

82.1 VDC ±1% 

Long-run 

Model* 

Battery Numbers 

Charging Current   

1.0A/2.0A/4.0A/6.0 A 

Charging Voltage 

27.4 VDC ± 

1% 

41.0VDC ± 

1% 

54.7 VDC 

±1% 

82.1VDC 

±1% 

109.4VDC 

±1% 

82.1 VDC 

±1% 

109.4VDC 

±1% 

PHYSICAL 

Standard 

Model 

Dimension, D X W X H   

282 X 145 X 220 (mm) 

397 X 145 X 220 (mm) 

421 X 190 X 318 (mm) 

Net Weight (kgs) 

9.8 

17 

27.6 

Long-run 

Model* 

Dimension, D X W X H   

282 x 145 x 220 (mm) 

397x 145 x 220(mm) 

Net Weight (kgs) 

4.1 

4.1 

6.8 

6.8 

6.8 

7.4 

7.4 

ENVIRONMENT 

Operation Humidity 

20-90 % RH @ 0- 40°C (non-condensing) 

Noise Level 

Less than 50dBA @ 1 Meter 

MANAGEMENT 

Smart RS-232 or USB 

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

*Long-run model is only available in 200/208/220/230/240VAC systems. 

** Derate capacity to 80% of capacity in Frequency converter mode or when the output voltage is adjusted to 100/200/208VAC. 

*** Product specifications are subject to change without further notice. 

 

Summary of Contents for PRO900-VL

Page 1: ...ONLINE UPS User Manual PROFESSIONAL I SERIES 1P 1P TOWER PRO900 VS VL 1 3KVA Version 1 00 English ...

Page 2: ...2 3 UPS Tower Rack Installation Only available for Rack UPS 9 2 4 Setup the UPS 10 2 5 Battery replacement Only for Rack UPS 12 2 6 Battery kit assembly Option for Rack UPS 13 3 Operations 15 3 1 Button operation 15 3 2 LED Indicators 16 3 3 UPS Setting 17 3 4 Operating Mode Description 18 3 5 Audible Alarm 19 3 6 Faults Reference Code 19 3 7 Warning indicator 19 4 Troubleshooting 20 5 Storage and...

Page 3: ...ver them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the buil...

Page 4: ...sulated grips and handles When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same type and amperage in order to avoid fire hazards Do not di...

Page 5: ...g inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear panel view 1K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type 2K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type I NEMA Type II ...

Page 6: ...4 3K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type 1KL 2KL India Type IEC Type Schuko Type Universal Type Argentina Type UK Type ...

Page 7: ...sal Type Argentina Type UK Type 1 AC input 2 Input circuit breaker 3 USB communication port 4 RS 232 communication port 5 SNMP intelligent slot option 6 External battery connection only available for L model 7 Output receptacles 8 Output terminal ...

Page 8: ...6 Not in use For Rack Type Models Only ...

Page 9: ...7 Not in use For Rack Type Models Only ...

Page 10: ...8 Not in use For Rack Type Models Only ...

Page 11: ...he UPS is shown as below 2 3 UPS Tower Rack Installation Only available for Rack UPS Rack mount Installation This UPS can be mounted in the 19 rack chassis Please follow below steps to position this UPS Step 1 Step 2 Tower Installation Step 1 Step 2 Step 3 ...

Page 12: ...15 120 127VAC models The power cord is attached to the UPS The input plug is a NEMA 5 15P for 1K model and NEMA 5 20P for 2K model Step 3 UPS output connection For socket type outputs simply connect devices to the outlets For terminal type input or outputs please follow below steps for the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cor...

Page 13: ...ss the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 6 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to...

Page 14: ...12 2 5 Battery replacement Only for Rack UPS ...

Page 15: ...13 2 6 Battery kit assembly Option for Rack UPS ...

Page 16: ...14 Not in use For Rack Type Models Only ...

Page 17: ... will be in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage and output frequency It will return back to default d...

Page 18: ...ry level It indicates battery level by 0 25 26 50 51 75 and 76 100 when UPS is in battery or standby mode It indicates load level by 0 25 26 50 51 75 and 76 100 when UPS is in online bypass ECO and converter mode Indicates overload Indicates low battery level and low battery voltage Mode operation information Indicates the UPS connects to the mains Indicates the battery is working Indicates the by...

Page 19: ...put voltage setting Interface Setting For 200 208 220 230 240 VAC models you may choose the following output voltage LED7 presents output voltage is 208Vac LED8 presents output voltage is 220Vac LED9 presents output voltage is 230Vac LED10 presents output voltage is 240Vac LED4 flashing Bypass enable disable when UPS is off Interface Setting Enable or disable Bypass function You may choose the fol...

Page 20: ...ill charge battery under this mode ECO mode Energy saving mode When the input voltage is within voltage regulation range UPS will bypass voltage to output for energy saving Battery mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Bypass mode When input voltage is within acceptable range but UPS is ov...

Page 21: ... LED7 LED8 and LED 9 on Boost fault LED5 and LED10 on High voltage in charger LED5 LED7 LED8 LED9 and LED10 on Temperature abnormal LED5 LED7 and LED8 on Low voltage in charger LED5 LED8 LED9 and LED10 on 3 7 Warning indicator Warning LED flashing Alarm Input wiring is not connected correctly LED1 LED5 Sounding every second Battery is not connected LED2 LED5 Sounding every second Battery fault LED...

Page 22: ...e and alarm is sounding twice every second UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the electrical network via the Bypass Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut ...

Page 23: ...aler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 25 C 40 C Every 3 months 1 2 hours 40 C 45 C Every 2 months 1 2 hours Be sure to deliver the spent battery to a recycling facility or ship it to your dealer in ...

Page 24: ...atio 3 1 Harmonic Distortion 3 THD linear load 6 THD non linear load Transfer Time AC Mode to Batt Mode Zero Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sinewave EFFICIENCY AC Mode 88 89 90 Battery Mode 83 87 88 BATTERY Standard Model Battery Type 12 V 9 AH 12 V 9 AH 12 V 9 AH Numbers 2 4 6 Recharge Time 4 hours recover to 90 capacity Typical Charging Current 1 0 A max Charging Voltage...

Page 25: ...TERS INDONESIA Office PT PROLiNK INTIDATA NUSANTARA Walk In Jl Cideng Barat No 79 Jakarta Pusat 10150 Indonesia Email Support support id prolink2u com MALAYSIA Office FIDA SYSTEMS M SDN BHD Walk In 29 Jalan USJ 1 31 47600 Subang Jaya Selangor Darul Ehsan Malaysia Email Support support my prolink2u com SINGAPORE Office FIDA INTERNATIONAL S PTE LTD Walk In Block 16 Kallang Place 06 02 Kallang Basin ...

Reviews: