7. Spesifikasi

ID 6

 

CAPACITY 

INPUT 

 

 

OUTPUT 

 

 

 

 

 

BATTERY 

 

 

PROTECTION/ 

MONITORING

 

 

 

 

 

 

 

INTERFACE

 

GENERAL

 

 

 

 

   

Voltage Range 

Frequency 

Phase  

Voltage Range

 

Battery Mode

 

Frequency

 

Waveform

 

  

Transfer Time

 

Type 

Backup Time 

Recharge Time 

Short Circuit Protection

 

Surge Protection 

Alarm 

Overload Protection

 

  

  

  

Intelligent Battery

 

Management

 

USB Connector

Software

  

Noise Level

 

Temperature 

Humidity 

Power Factor 

Built in AVR 

 

 

850VA

140 - 300VAC ±5% 

50Hz/60Hz (Auto-sensing)

GND

12% -14%

230VAC ±10%

 

50Hz ±1% (Battery Mode)

Simulated Sine Wave (Battery Mode)

Sine Wave (AC Mode)

Typical 2 - 6ms

12V/10AH - 1pc

8 - 30 mins depending on load

2 - 4 hours recover to 90% capacity

Yes (Line Mode and Battery Mode)

Yes

Audible & Visual

Line Mode -     

>120% change to fault mode immediately

Battery Mode - 

>120% shutdown immediately

Prevent overcharging of battery

Protect battery and prolong battery life

AC Fault, Battery Low, Shutdown UPS 

Support Windows® 2000/2003/XP/Vista/2008/7, Linux, 

Unix, and MAC

 

<40dB

0˚C - 40˚C

0 - 90%

Up to 0.7

TRUE Full AVR (3 steps)

100 - 120% 5mins change to fault mode

100 - 120% 5 secs shutdown

Indonesian

Summary of Contents for PRO850SFCU

Page 1: ...s or need further information pertaining to the device please visit our website at www prolink2u com All specifications are subject to the manufacturer s configuration at the time of shipping and may...

Page 2: ...ric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and...

Page 3: ...e optional 4 Items 2 1 3 optional 4 optional BEFORE GETTING STARTED This document is designed to aid you to get started with the device If you experience problems following these guides or need furthe...

Page 4: ...5 1 2 Legend LED Indication 1 Power Switch 2 USB port 3 4 Power AC Input 5 RJ11 Ports Modem Fax Protection 6 Backup Outlets Fault LED Red lighting Battery mode LED Yellow flashing AC mode LED Green li...

Page 5: ...0 cm to avoid interference DO NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations 6 Hours Connect to Utility and Charging P...

Page 6: ...itical load Battery voltage is too low Charge the UPS at least 6 hours Battery defect It might be due to high temperature operation environment or improper operation to battery Replace the battery wit...

Page 7: ...230VAC 12 14 230VAC 10 50Hz 1 Battery Mode Simulated Sine Wave Battery Mode Sine Wave AC Mode Typical 2 6ms 12V 10AH 1pc 8 30 mins depending on load 2 4 hours recover to 90 capacity Yes Line Mode and...

Page 8: ...awah 3 5mA Perhatian tersengat listrik sangat berbahaya Juga dengan melepaskan unit ini dari sumber listrik tegangan berbahaya masih tersimpan pada baterai Kabel baterai juga harus dilepas disaat mela...

Page 9: ...t kabel USB optional 4 Items 2 1 3 optional 4 optional BEFORE GETTING STARTED This document is designed to aid you to get started with the device If you experience problems following these guides or n...

Page 10: ...sar Legend Indikator LED 1 Power Switch 2 Port USB 3 4 Power AC Input 5 Port RJ11 Modem Perlindungan Faks 6 Konektor Output LED fault Menyala Merah LED modus baterai Berkedip Kuning LED modus AC Menya...

Page 11: ...ang lain untuk menghindari interferensi JANGAN menjalankan UPS disaat suhu dan kelembaban berada diluar batas yang telah ditentukan Silahkan periksa spesifikasi untuk mengetahui batasan 20cm 20cm Samb...

Page 12: ...idupkan UPS Masalah Kemungkinan Solusi Tidak ada LED yang menyala pada panel depan Baterai lemah Charge UPS minimal 6 jam Baterai rusak UPS belum dihidupkan Alarm secara terus menerus berbunyi ketika...

Page 13: ...sensing Single GND 230VAC 12 14 230VAC 10 50Hz 1 Battery Mode Simulated Sine Wave Battery Mode Sine Wave AC Mode Typical 2 6ms 12V 10AH 1pc 8 30 mins depending on load 2 4 hours recover to 90 capacity...

Page 14: ...Indonesia Telephone 62 21 3483 1777 Email Support support prolink co id MALAYSIA Office FIDA SYSTEMS M SDN BHD Walk In 29 Jalan USJ 1 31 47600 Subang Jaya Selangor Darul Ehsan Malaysia Telephone 60 3...

Page 15: ......

Page 16: ......

Reviews: