1.2KVA/ 2.4KVA Inverter 

 

 

 
 
 

 
 
 
 

 
 
 

 

V.  1.1 

1. Introduction 

Thank you for purchasing the solar inverter. This simple solar inverter is designed to power 
your home appliances or precious 3C electronics. It also can handle motor-type loads with high 
surge power such as vacuums, small freezers, or drills. With built-in solar charger, it can 
convert solar power to battery power and provide continuous power to connected equipment 
during night time.     
 

2. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

Before using the inverter, please read all instructions and cautionary markings 
on the unit, this manual and the batteries. 
General Precaution- 

Install the UPS in a protected area that is free of excessive dust and has adequate air flow. 
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT 
operate the UPS where the temperature and humidity is outside the specific limits. (Please 
check the specs for the limitations.) 

CAUTION!

 The unit is designed for indoor use. Do not expose this unit to rain, snow or 

liquids of any type. 

CAUTION! 

To reduce risk of injury, only use qualified batteries from qualified distributors or 

manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or 
overdue batteries. Please check the battery type and date code before installation to avoid 
damage and injury. 

WARNING! 

It's very important for system safety and efficient operation to use appropriate 

external battery cable. To reduce risk of injury, external battery cables should be UL certified 
and rated for 7

  C or higher. And do not use copper cables less than 10AWG. Below is the 

external battery cable reference according to system requirements. 

 
Table 1    Minimum Recommended Battery Cable Size versus Length 

Model 

Typical Amp. 

1 meter (one-way) 

Dia-mm 

1.2KVA 

75 A 

AWG 6(or 2*AWG10) 

4.1151 

2.4KVA 

75 A 

AWG 6(or 2*AWG10) 

4.1151 

 

Quick Guide   

Conventions used: 
WARNING! 

Warnings identify conditions or practices that could result in personal injury;   

CAUTION!   

Caution identify conditions or practices that could result in damaged to the 

unit or other equipment connected. 

Summary of Contents for IPS1200A

Page 1: ... The unit is designed for indoor use Do not expose this unit to rain snow or liquids of any type CAUTION To reduce risk of injury only use qualified batteries from qualified distributors or manufacturers Any unqualified batteries may cause damage and injury Do NOT use old or overdue batteries Please check the battery type and date code before installation to avoid damage and injury WARNING It s ve...

Page 2: ...ompartment CAUTION Use insulated tools to reduce the chance of short circuit when installing or working with the inverter the batteries or other equipments attached to this unit CAUTION For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating Personnel Precaution CAUTION Careful to reduce the risk or dropping a metal tool...

Page 3: ...e Please refer to Important Safety Warnings Section for the details Step 3 Tight the battery cables with the M5 nuts Do NOT place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur See Fig 1 Step 4 Install a DC Breaker in a positive battery line The rating of the DC Breaker must be according to the inverter s battery current 75 Amp Keep ...

Page 4: ...connection Refer to below table Model Best Vmp Vmp range 1 2KVA 15Vdc 15V 18V 2 4KVA 30Vdc 30V 32V Note Vmp panel max power point voltage The PV charging efficiency is maximized while PV system voltage is close to Best Vmp Maximum PV module numbers in Series Vmpp of PV module X pcs Best Vmp of Inverter or Vmp range PV module numbers in Parallel Max charging current of inverter Impp Total PV module...

Page 5: ... Off Battery fully charged at power off and Off flashing every 11 sec Battery mode Battery weak and will flash every 2 second Sounding every 1 sec None weak battery Off Fault mode Fault code will be displayed Short fault F0 Overload fault F1 Battery bad F2 High output voltage F3 Main Relay Stick F4 Fan fault F5 Continuously sounding for 30 min and then alarm off The unit is overload The mark will ...

Page 6: ...nel Battery is not connected well Check the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Buzzer beeps continuously and red LED is on LCD display F0 Output short circuited Check if wiring is connected well and remove abnormal load LCD display F1 Overload error The inverter is loaded with more than 110 load...

Reviews: