![Proline SLC 116PEW Service Manual Download Page 19](http://html1.mh-extra.com/html/proline/slc-116pew/slc-116pew_service-manual_1614902019.webp)
18
Code
˖
Error Message: Prompting the door not closed tightly.
Y
Y
N
Pushing the door to check whether
door is properly shut or not .
Check whether the terminals are
installed correctly.
Check whether the heater short
circuit or cut off
Chek whether the lint screen is
blocked
shut the door properly
N
Code
⧜
Error message: The temperature tested by NTC does not change.
Y
Replace the heater which
can not work
Y
clear the lint screen
Install the terminals
properly
N
Fix up the terminals
proerly
N
N
Check whether the NTC is
short circuit or cut off ( the
resistance number of NTC
is nearby 10K )
Y
Replace the NTC
Touching slice
Terminals
+HDWHU
Check whether the touching
slice is fixed properly.
Condenser Tumber Dryer
SLC 116PEW