PROLIGHTS - SmartBat
PlusG2
22
RDM PIDs
Parameter
Category
PID
Address GET SET Value
Description Default
Value
AC MODE:
Manufacturer
PIDs
x
x
0-1
0:NO
ACTION,
1:BLACKOUT
BATTERY RECHARGE
Manufacturer
PIDs
x
x
0-2
0:AUTO,
1:DISABLE,
2:ENABLE
DMX FAULT
Manufacturer
PIDs
x
x
0-3
0: HOLD
1: BLCK 2:SA
3:EMGENCY
MASTER/SLAVE
Manufacturer
PIDs
x
x
0-2
0:MST DMX
1:MST NO
DMX 2:SLAVE
ST. AL. MODE
Manufacturer
PIDs
x
x
0-4
0:STATIC;
1:CCT;
2:MACRO;
3:RGBW; 4:FX
STATIC COLORS
Manufacturer
PIDs
x
x
0-15
Refer to menu
section
WHITE PRESETS
Manufacturer
PIDs
x
x
0-13
Refer to menu
section
COLOR MACROS
Manufacturer
PIDs
x
x
0-64
Refer to menu
section
MANUAL RED
Manufacturer
PIDs
x
x
0-255
Refer to menu
section
MANUAL GREEN
Manufacturer
PIDs
x
x
0-255
Refer to menu
section
MANUAL BLUE
Manufacturer
PIDs
x
x
0-255
Refer to menu
section
MANUAL WHITE
Manufacturer
PIDs
x
x
0-255
Refer to menu
section
FX
Manufacturer
PIDs
x
x
0-4
Refer to menu
section
WH. CAL.: 0:OFF 1:STUDIO
2:MANUAL 3:CALIBRATED
Manufacturer
PIDs
x
x
0-3
Refer to menu
section
STUDIO-RED
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
STUDIO-GREEN
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
STUDIO-BLUE
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
STUDIO-WHITE
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
MANUAL-RED
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
MANUAL-GREEN
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
MANUAL-BLUE
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
MANUAL-WHITE
Manufacturer
PIDs
x
x
0-255
PID for service
purpose
IR SETUP 0:OFF 1:ON
Manufacturer
PIDs
x
x
0-1
Enable/Disable
IR control
RUN TIME
Manufacturer
PIDs
x
x
0-4
0:3H 1:6H 2:8H
3:12H 4:18H
CLEAN ALL DATA
Manufacturer
PIDs
x
x
0-1
0:NO,1:YES
Summary of Contents for SmartBat PlusG2