background image

LUMIPIX6TRI

2

WARNING! Before carrying out any operations with the unit, carefully read this instruction 
manual and keep it with cure for future reference. It contains important information about 
the installation, usage and maintenance of the unit.

SAFETY

General instruction

• 

The products referred to in this manual conform to the European Community Directives and are there-

fore marked with  .

• 

The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only. 

Never make any modifications on the unit not described in this instruction manual, otherwise you will 

risk an electric shock.

• 

Connection must be made to a power supply system fitted with efficient earthing (Class I appliance ac-

cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units 

from indirect contact and/or shorting to earth by using appropriately sized residual current devices.

• 

The connection to the main network of electric distribution must be carried out by a qualified electrical 

installer. Check that the main frequency and voltage correspond to those for which the unit is designed 

as given on the electrical data label. 

• 

This unit is not for home use, only professional applications.

• 

Never use the fixture under the following conditions:

- in places subject to vibrations or bumps;

- in places with a temperature of over 40°C.

• 

Make certain that no inflammable liquids, water or metal objects enter the fixture.

• 

Do not dismantle or modify the fixture.

• 

All work must always be carried out by qualified technical personnel. Contact the nearest sales point for 

an inspection or contact the manufacturer directly.

• 

If the unit is to be put out of operation definitively, take it to a local recycling 

plant for a disposal which is not harmful to the environment.

Warnings and installation precautions

• 

If this device will be operated in any way different to the one described in this manual, it may suffer 

damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like 

short circuit, burns, electric shock, etc.

• 

Before starting any maintenance work or cleaning the projector, cut off power from the main supply.

• 

The unit for indoor use only. To prevent or reduce the risk of electrical shock or fire, do not expose the 

unit to rain or moisture.

• 

Always additionally secure the projector with the safety rope. When carrying out any work, always com-

ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country 

in which the fixture’s being used.  

• 

Always install the product in a location with adequate ventilation, at least 50 cm from adjacent surfaces.

• 

Keep any inflammable material at a safe distance from the fixture.

• 

Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent 

that their effectiveness is impaired.

• 

The lamp (LED) shall be changed if it has become damaged or thermally deformed.

• 

Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may 

trigger epileptic seizures in photosensitive persons or persons with epilepsy.

Summary of Contents for LUMIPIX6TRI

Page 1: ...EN IT Manuale Utente User Manual LUMIPIX6TRI DIGITAL PIXEL LED TRICOLOR BATTEN...

Page 2: ...arziale per propri scopi commerciali vietata Al fine di migliorare la qualit dei prodotti la Music Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche...

Page 3: ...taggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazione base 3 3 Struttura menu 3 4 Modalit automatica 3 5 Preset color 3 6 Modalit static color 3 7 Modalit Master Slave 3 8 Collegamento 3...

Page 4: ...tti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza...

Page 5: ...delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inv...

Page 6: ...ello di controllo tramite display LCD Diverse configurazioni DMX disponibili 3 4 6 7 9 18 canali per controllo professionale o semplificato 3 canali RGB 4 canali RGB dimmer 6 canali RGB 2 section 7 ca...

Page 7: ...100 240V 50 60Hz tramite il cavo di rete in dotazione Sotto la spina si trova il portafusibile Sostituire un fusibile difettoso solo con uno dello stesso tipo 5 REGOLATORE SENSIBILIT AUDIO nella moda...

Page 8: ...ficiente e suppor tare almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissare il proiettore attraverso le apposite staffe ad una colloc...

Page 9: ...t consigliabile collegare l unit con una presa comandata da un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore LUMIPIX6TRI dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannel...

Page 10: ...er confermare MAIN FUNCTION SELECTION SUB SELECTION DESCRIPTION Static Color C C 01 Red C 02 Green C 03 Blue C 04 Cyan C 05 Magenta C 06 Yellow C 07 White Auto Program P P 1 7 Color switching P 2 7 Co...

Page 11: ...ENTER per confermare Attraverso i tasti UP DOWN selezionare il colore desiderato Premere il tasto ENTER Utilizzare i tasti UP DOWN per impostare il valore desiderato 001 100 Premere il tasto ENTER pe...

Page 12: ...anale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per comandare la funzione del primo canale DMX si deve impostare sul LUMIPIX6TRI l indirizzo di start 33 Le altre funzioni del pan...

Page 13: ...i dati di controllo DMX Collegare l uscita DMX del controller con l ingresso DMX della prima unit Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l...

Page 14: ...0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 COLOR MACROS No function Color macros 000 015 016 255 5 SPEED 0 100 STROBE CH1 CH4 ONLY No function 0 30Hz 000 255 000 015 016 255 6 AUTO PR...

Page 15: ...E 0 100 000 255 SECTION 2 4 RED 0 100 000 255 5 GREEN 0 100 000 255 6 BLUE 0 100 000 255 CH9 Section CH Function in CH9 mode Value SECTION 1 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000...

Page 16: ...0 000 255 6 BLUE 0 100 000 255 SECTION 3 7 RED 0 100 000 255 8 GREEN 0 100 000 255 9 BLUE 0 100 000 255 SECTION 4 10 RED 0 100 000 255 11 GREEN 0 100 000 255 12 BLUE 0 100 000 255 SECTION 5 13 RED 0 1...

Page 17: ...mente nel momento in cui anche un piccolo problema viene rilevato Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportare polvere fumo e altre particelle Solo cos...

Page 18: ...nte Il proiettore non alimentato Mancanza di alimentazione di rete Cavo di alimentazione danneggiato Alimentatore interno difettoso Verificarelapresenzadellatensionealimentazione Controllare il cavo d...

Page 19: ......

Page 20: ...by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and w...

Page 21: ...ections 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Automatic 3 5 Static color 3 6 Custom static color 3 7 Master Slave mode 3 8 Linking 3 9 DMX...

Page 22: ...dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit...

Page 23: ...te www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form ava...

Page 24: ...tures User panel through LCD display Several DMX selectable configurations 3 4 6 7 9 18 channels for advanced or basic controlling 3 channels RGB 4 channels RGB dimmer 6 channels RGB 2 section 7 chann...

Page 25: ...near the mains plug Only replace a blown fuse by one of the same type 5 CONTROL SENSITIVITY for the sensitivity of response in case of music control via the internal microphone 6 MICROPHONE to control...

Page 26: ...scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mo...

Page 27: ...onvenient operation it is recom mended to connect the unit to a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located...

Page 28: ...N FUNCTION SELECTION SUB SELECTION DESCRIPTION Static Color C C 01 Red C 02 Green C 03 Blue C 04 Cyan C 05 Magenta C 06 Yellow C 07 White Auto Program P P 1 7 Color switching P 2 7 Color fading P 3 3...

Page 29: ...d color Press ENTER button Using UP DOWN button select the desired color value 001 100 By selecting 000 the color will remain off Press ENTER button to continue to the next color R G b Using UP DOWN b...

Page 30: ...IPIX6TRI with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust t...

Page 31: ...e it cannot transmit control DMX data reliably Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the outp...

Page 32: ...00 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 COLOR MACROS No function Color macros 000 015 016 255 5 SPEED 0 100 STROBE CH1 CH4 ONLY No function 0 30Hz 000 255 000 015 016 255 6 AUTO PROGRA...

Page 33: ...E 0 100 000 255 SECTION 2 4 RED 0 100 000 255 5 GREEN 0 100 000 255 6 BLUE 0 100 000 255 CH9 Section CH Function in CH9 mode Value SECTION 1 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000...

Page 34: ...0 000 255 6 BLUE 0 100 000 255 SECTION 3 7 RED 0 100 000 255 8 GREEN 0 100 000 255 9 BLUE 0 100 000 255 SECTION 4 10 RED 0 100 000 255 11 GREEN 0 100 000 255 12 BLUE 0 100 000 255 SECTION 5 13 RED 0 1...

Page 35: ...when a small problem is detected It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brig...

Page 36: ...lens assembly Clean the fixture regularly Install lens assembly properly Fixture does not power up No power Loose or damaged power cord Faulty internal power supply Check for power on power outlet Ch...

Page 37: ......

Page 38: ......

Page 39: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Page 40: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Page 41: ......

Page 42: ......

Page 43: ......

Page 44: ...39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company 2012 Music Lights S r l PROLIGHTS un brand di propriet della Music L...