background image

PROLIGHTS - Ecl 

FW

07

Weight:

ECLPRL19: 9.6 kg - 21.16 lbs

ECLPRL26 9.7 - 21.38 lbs

ECLPRL36 9.4 - 20.72 lbs

ECLPRL50: 9.1 - 20.06 lbs

ECLFW with ECLPRL19-26-36-50

Weight: 9.1 kg - 21.06 lbs

ECLFW with ECLPRL70

Weight: 11.3 kg - 24.91 lbs

ECLFW with ECLPRLZ1530

Weight: 11.3 kg - 24.91lbs

ECLFW with ECLPRLZ2550

Fig.1

Summary of Contents for EclProfile FW

Page 1: ...USER MANUAL REV 02 12 20 English version EclProfile FW High quality Full White LED ellipsoidal available in Tungsten and Daylight versions...

Page 2: ...economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolight...

Page 3: ...ON OF THE DMX TERMINATION 12 DMX ADDRESSING 12 8 CONTROL PANEL 13 DISPLAY AND BUTTONS LAYOUT 13 9 MENU STRUCTURE 14 10 RDM FUNCTIONS 16 11 SHORTCUTS 17 12 ERROR MESSAGES 17 13 DMX CHARTS 18 14 ACCESSO...

Page 4: ...e in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are dam...

Page 5: ...id and particle build up degrades performance causes overheating and will damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 70 C c Tempe...

Page 6: ...luminaire at a distance closer than 3 72 m is not expected Disposal This product is supplied in compliance with European Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE To preserv...

Page 7: ...15 30 PRL lens barrel for EclProfile fixtures black housing ECLPRLZ2550BK zoom 25 50 PRL lens barrel for Ecl Profile fixtures black housing ECLLZ1530 optics for ECLFC HD ECLFS ECLFW ECLCTPLUS profile...

Page 8: ...Ecl FW 06 2 TECHNICAL DRAWING Weight 7 3 kg 16 09 lbs ECLFW without optic Weight 10 2 kg 22 48 lbs ECLFW with ECLPRL05 Weight 9 2 kg 20 28 lbs ECLFW with ECLPRL10 Weight 10 6 kg 23 37 lbs ECLFW with...

Page 9: ...lbs ECLPRL26 9 7 21 38 lbs ECLPRL36 9 4 20 72 lbs ECLPRL50 9 1 20 06 lbs ECLFW with ECLPRL19 26 36 50 Weight 9 1 kg 21 06 lbs ECLFW with ECLPRL70 Weight 11 3 kg 24 91 lbs ECLFW with ECLPRLZ1530 Weigh...

Page 10: ...re it against failure of primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use re...

Page 11: ...rom the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switching...

Page 12: ...to attach safety cable 8 HANDLE 9 USER INTERFACE with display and buttons for access to the control panel functions 10 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 11 DMX OUT 5 p XLR 1 GND 2 sign 3...

Page 13: ...onnection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male connecto...

Page 14: ...xecuting the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the DMX...

Page 15: ...ns for access to the control panel functions MENU Used to access the menu tree or to return a previous menu window UP Browse upwards through the menu list and increases the numeric value displayed DOW...

Page 16: ...ngs of one fixtures to all the other in the daisy chain including or not the dmx address Temperature Unit C F To choose the desired unit of temperature measurement 3 Advanced Dimmer Curve Linear S Cur...

Page 17: ...is chase into play by putting the switch on For each scene you can set fade time and hold time Mix 16 Switch Hold Time Fade Time Dimmer On Off On 5 Information Fixture H To view infromation about the...

Page 18: ...ESPONSE_TIME 0x0345 x x OUTPUT_RESPONSE_TIME_ DESCRIPTION 0x0346 x MODULATION_FREQUENCY 0x0347 x x MODULATION_FREQUENCY_ DESCRIPTION 0x0348 x Sensors SENSOR_DEFINITION 0x0200 x SENSOR_VALUE 0x0201 x x...

Page 19: ...12 ERROR MESSAGES 11 SHORTCUTS LAMP_STATE 0x0403 x x LAMP_ON_MODE 0x0404 x x DEVICE_POWER_CYCLES 0x0405 x x Display Settings DISPLAY_INVERT 0x0500 x x DISPLAY_LEVEL 0x0501 x x Configuration LOCK_PIN 0...

Page 20: ...Y 20S DISPLAY 30S FLIP DISPLAY ON FLIP DISPLAY OFF KEY LOCK ON KEY LOCK OFF DIMMER CURVE LINEAR DIMMER CURVE S CURVE DIMMER CURVE SQUARE LAW DIMMER CURVE INVERSE SQUARE LAW DIMMER SPEED AUTO DIMMER SP...

Page 21: ...PROLIGHTS Ecl FW 19 14 ACCESSORIES INSTALLATION OPTIC CODE ECLPRL OPTIONAL 1 Loosen and remove the two marked knobs 2 Mount the desired optic 3 Insert and tighten the knobs Fig 8...

Page 22: ...ONAL 1 2 1 Push the clip located at the top of the optics body outwards 1 and lift it 2 1 2 3 2 Then insert the filter 1 into the marked track 2 and close the clip 3 always applying an outward push NO...

Page 23: ...PROLIGHTS Ecl FW 21 GOBO HOLDER CODE ECLPRGH OPTIONAL Gobo dimensions Type B external 86 mm of image 64 5 mm Thinckness 1 1 mm 86 3 4 65 2 5 1 1 0 04 Put in place the Gobo Fig 10...

Page 24: ...2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 2 Insert the gobo holder 1 into the slot The flaps will go into the appropriate size 2 NOTE To remove the accessory reverse...

Page 25: ...PRIRIS OPTIONAL 1 2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 2 Insert the steel iris diaphram 1 into the slot The flaps will go into the appropriate size 2 NOTE To re...

Page 26: ...OFT EDGE FILTER CODE ECLPRSEF1 OPTIONAL 1 2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 Insert the Soft edge filter into the slot 1 NOTE To remove the accessory reverse...

Page 27: ...4 3 1 Loosen the marked knob 1 and screw 2 Then rotate 3 the middle part and remove it 4 1 2 3 2 Insert the soft focus diffusion kit by placing the magnets 1 on the back of the framing system 2 of th...

Page 28: ...E POLE OPERATED YOKE CODE ECLPRPOYO OPTIONAL 1 Loosen and remove the marked screws 2 Remove the bracket 3 Mount the Pole Operated Yoke bracket 4 Tighten the screws NOTE To remove the accessory reverse...

Page 29: ...personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component li...

Page 30: ...s and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fi...

Page 31: ...Note...

Page 32: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Reviews: