12
Fig.8 - Example configuration
Ethernet
Switch
Art-Net/sACN
Art-Net/sACN
(DMX address=250)
(DMX address=48)
(DMX address=144)
IP address=002.168.002.004
Universe=1
(DMX address=250)
(DMX address=48)
(DMX address=144)
IP address=002.168.002.004
Universe=1
DMX 512
DMX 512
DMX 512
DMX 512
Fig.7
1
RJ-45 socket (front view):
1-TD
2-TD-
3-RX+
4-Not connected
5-Not connected
6-RX-
7-Not connected
8-Not connected
2 3 4 5 6 7 8
8
RJ-45 socket (front view):
7 6 5 4 3 2 1
ETHERNET TO DMX OPERATIONS
Please refer to the section MENU STRUCTURE contained in this document for detailed informations
This function allow a product receiving an ethernet signal protocol to re-transmit the incoming signal
onto a wired DMX line through its onboard XLR-out connector.
• An Ethernet protocol (Artnet, sACN or others available) has to be enabled from Ethernet menu
at first fixture.
Please make sure that wireless receiver is switched to OFF if you use Ethernet
comunication.
•
Enable the option Ethernet To DMX from the Ethernet menu at the first product (connected to the
Ethernet) in the signal chain, next products have standard DMX setting.
•
Connect the Ethernet input of the first product in the data chain with the network. Connect the
DMX output of this product with the input of the next product until all products are connected to
the DMX chain.
•
Caution: At the last product, the DMX chain has to be terminated with a terminator. Solder a 120 Ω
resistor between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the