7
DIGIDRIVERIP - DIGISTRIPIP50 - DIGISTRIPIP100
Fig.5
- 2 - INSTALLATION
2.1 MOUNTING
The management and power unit DIGIDRIVERIP should be placed on a non-flammable flat surface in any
orientation or fixed by four screws in a 19” rack. There are four mounting holes on the housing as shown
in figure 7.
2.2 MAXIMUM CABLE DISTANCE
Max cable distance between two fixtures:
• No maximum distance between the 2 devices. The last DIGISTRIP need to stay under 60m distance
Max cable distance between DIGIDRIVERIP - first fixture connected:
• DIGIDRIVERIP - DIGISTRIP100 = 60 m
• DIGIDRIVERIP - DIGISTRIP50 = 60 m
Max distance between DIGIDRIVERIP - last fixture connected:
• DIGIDRIVERIP - DIGISTRIP100 = 60 m
• DIGIDRIVERIP - DIGISTRIP50 = 60 m