background image

ARCLED7348RGBW

4

1.2 Description

ARCLED7348RGBW is a high-tech and powerful colorchangers, designed for indoor and outdoor artistic 

lighting applications. Based on RGB color mixing system, ingress protection IP67, ARCLED7348RGBW high 

versatility allows for creative and spectacular entertainment lighting effects as well as for artistic architec-

tural lighting applications. ARCLED7348RGBW fixtures are effective tools to highlite monuments, museums, 

historical buildings and key sites as well. Quality & features of ARCLED projectors allow lighting designers, 

architects and decorators to express their creative imagination in different lighting environments.

1.3 Technical specification

Professional RGB washlight projector, based on LED technology, for indoor/outdoor applications

Light source and optics

•  48 x 3W high-efficiency LEDs: (12 red, 12 green, 12 blue, 12 white).

•  Energy-saving LEDs employed, with more vivid colours and lower power consumption than traditional 

lamps.

•  Colour synthesis: RGBW Colour mixing (>16million colours) for a limitless colour range, white control for 

more precise colour temperature adjustment.

•  Optics: high definition anti-reflection lenses.

•  Projection angle: 15° (25°, 45°, 60° available on demand).

•  Colour temperature presets (3200K ~ 10000K).

•  LEDs average life span: > 75’000 hours.

Electronics and features

•  Several DMX configurations selectable (3, 4, 5, 6 and 10 channels) for professional or simplified control-

ling.

•  3 channels (ARC mode): RGB.

•  3 channels (HSV mode): HSV (Hue, Saturation, Value).

•  4 channels (ARC2 mode): RGBW.

•  4 channels (ARCD mode): RGB, dimmer.

•  5 channels (AR2D mode): RGBW, dimmer.

•  5 channels (ARCS mode): RGB, dimmer, strobe.

•  6 channels (AR2S mode): RGBW, dimmer, strobe.

•  10 channels (STAG mode): RGBW, dimmer, strobe, macro, auto, custom settings, ID addressing.

•  Manual control of values and programs through the LED display menu.

•  Automatic mode with built-in programs.

•  Master/Slave mode for stand alone operations.

•  Linear and “stepless” transition between DMX values.

•  Flicker free operations.

•  Aluminum panel included to protect electronics and display against water infiltrations and outdoor ap-

plications.

•  Silent operations and virtually no maintenance due to natural convection cooling system (no fans).

Structure and power supply

•  Sturdy die-cast aluminum body conceived for long-time durability and demanding applications.

•  IP67 protection rate and connections (standard SHUKO and XLR 3p adapters included).

•  Double hanging bracket suitable for safe hanging and as a floor stand.

•  Adjustable barn doors to direct light output (ARCLED7348BD not included).

•  Power unit: 100-240V 50/60Hz.

•  Power output signal: up to 15 units at 230V.

•  Consumption: 160W.

•  Weight: 9kgs.

•  Dimensions (WxHxD): 306x237x289 mm.

Summary of Contents for ARCLED7348RGBW

Page 1: ...I GB Manuale Utente User Manual ARCLED7348RGBW ARCHITAINMENT LED PROJECTOR ...

Page 2: ...REV 005 10 10 ...

Page 3: ...e Informazioni generali 1 Descrizione e specifiche tecniche 1 1 Elementi di comando e collegamenti 1 2 Descrizione 1 3 Specifiche tecniche 2 Installazione 2 1 Montaggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazione base 3 3 Struttura del menu 3 4 Funzionamento in modalità automatica 3 5 Modalità Master Slave 3 6 Collegamento 3 7 Configurazioni canali DMX 3 8 Modalità DMX 3 9 Indiriz...

Page 4: ...rete di alimentazione Assicurarsi che l unità sia spenta e che la temperatura delle parti non possa provocare ustioni È assolutamente necessario proteggere l unità per mezzo di una fune di sicurezza Nell eseguire qualsiasi intervento attenersi scrupolosamente a tutte le normative in materia di sicurezza vigenti nel paese di utilizzo Mantenere materiali infiammabili ad una distanza di sicurezza dal...

Page 5: ...1 Staffa di montaggio 2 Manopola di fissaggio per la staffa di montaggio 3 DMX OUT Connettori a 3 poli 1 massa 2 DMX 3 DMX 4 DMX IN Connettori a 3 poli 1 massa 2 DMX 3 DMX 5 POWER IN 6 POWER OUT max 15 unità 7 PANNELLO DI CONTROLLO 8 PUNTO DI ANCORAGGIO cavo di sicurezza Fig 1 6 4 3 5 7 2 1 8 ...

Page 6: ... ore Funzionamento ed elettronica Diverse configurazioni DMX disponibili 3 4 5 6 10 canali per controllo professionale o semplificato 3 canali ARC mode RGB 3 canali HSV mode HSV tonalità saturazione valore 4 canali ARC2 mode RGBW 4 canali ARCD mode RGB dimmer 5 canali AR2D mode RGBW dimmer 5 canali ARCS mode RGB dimmer strobo 6 canali AR2S mode RGBW dimmer strobo 10 canali STAG mode RGBW dimmer st...

Page 7: ...a 1 ad una collocazione idonea È assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta del proiettore non possa superare i 20 cm Orientare il proiettore intervenendo se necessario sulla manopola della staffa di montaggio 2 Fig 2 1 2 Beam Diameter mt 0 2 4 6 8 Dist mt Diam mt Lux ...

Page 8: ... proiettore ARCLED7348RGBW dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Nota Dopo circa 6 secondi fra due pressioni dei tasti la procedura d impostazione entra in modalità stand by Fig 3 MENU ENTER UP DOWN Per scorrere il menu principale o tornare ad una opzione del menu precedente Per entrare nel menu selezionato o confermare il valore attuale d...

Page 9: ...DON IDOF ENTER UP DOWN ID00 ID50 AUTO ENTER UP AT8F AT1F DOWN AT1F AT1O ENTER SP01 T008 UP DOWN UP DOWN T008 T255 SP01 SP25 TEST ENTER UP DOWN TESR TESG TESb T065 ENTER UP DOWN X255 X000 TESW Soft DMX STAG ARC ARC2 ARCD AR2D ARCS AR2S HSV ENTER UP DOWN UP DOWN SFON SFOF 10 Ch 3 Ch 4 Ch 4 Ch 5 Ch 5 Ch 6 Ch 3 Ch ...

Page 10: ... modalità O ovvero in questo caso proprio il programma n 3 3 5 Modalità Master Slave Questa modalità consente di collegare in linea più unità ARCLED7348RGBW senza un controller La prima unità sarà impostata come master MAST e le altre funzioneranno come slave SLAV con lo stesso effetto Le unità slave dovranno presentare l indirizzo DMX con valore 1 e la configurazione STAG per i canali di controll...

Page 11: ...upati Prossimo indirizzo di start possibile per unità n 1 Prossimo indirizzo di start possibile per unità n 2 Prossimo indirizzo di start possibile per unità n 3 10 33 33 42 43 53 63 Per l indirizzamento DMX senza indirizzo ID premere il tasto MENU fino a quando sul display non appare IDOF NOTA Quando si utilizza un unità di controllo luce è necessario assicurarsi che il canale 10 risulti inattivo...

Page 12: ...traverso i tasti UP e DOWN 3 12 Collegamenti della linea DMX La connessione DMX è realizzata con connettori standard XLR Utilizzare cavi schermati 2 poli ritorti con impedenza 120Ω e bassa capacità Per il collegamento fare riferimento allo schema di connessione riportato di seguito 1 3 2 1 2 3 DMX OUTPUT Presa XLR DMX INPUT Spina XLR Pin1 Massa Schermo Pin2 Negativo Pin3 Positivo ATTENZIONE La par...

Page 13: ...iunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unità della catena con connettori XLR a 5 pin o 3 pin saldando una resistenza di 120Ω minimo 1 4W tra i terminali 2 e 3 così come indicato in figura ...

Page 14: ... 255 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 Channel Function in STAG mode DMX value 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 COOL WHITE 0 100 000 255 6 COLOR MACRO 7 preset color effect 000 255 7 STROBE speed adjustable from slow to fast 000 255 8 AUTO program 8 programs 000 255 9 Program Fade In Out time Program run speed 000 128 129 255 10 ID AD...

Page 15: ...55 4 BLUE 0 100 000 255 Channel Function in AR2D mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 WHITE 0 100 000 255 Channel Function in ARCS mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 ...

Page 16: ...DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 WHITE 0 100 000 255 6 STROBE 0 100 000 255 Channel Function in HSV mode DMX value 1 HUE 0 100 000 255 2 SATURATION 0 100 000 255 3 VALUE 0 100 000 255 ...

Page 17: ... total mente esenti da qualsiasi deformazione I cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato L interno del dispositivo deve essere pulito ogni anno utilizzando un aspirapolvere o un getto d aria Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per as...

Page 18: ......

Page 19: ...s General information 1 Description and technical specifications 1 1 Operating elements and connections 1 2 Description 1 3 Technical specifications 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Operation in automatic mode 3 5 Master Slave Mode 3 6 Linking 3 7 DMX configurations 3 8 DMX Mode 3 9 DMX control without ID address 3 10 DMX addressin...

Page 20: ...ight may trigger epileptic seizures in photosensitive persons or persons with epilepsy Before starting any maintenance work or cleaning the projector cut off power from the main supply Make certain that the fixture is off and the temperature of the components cannot cause burns Always additionally secure the projector with the safety rope When carrying out any work always comply scrupu lously with...

Page 21: ...rating elements and connections 1 Mounting bracket 2 Locking knob for the mounting bracket 3 DMX OUT 3 pole Connector 1 ground 2 DMX 3 DMX 4 DMX IN 3 pole Connector 1 ground 2 DMX 3 DMX 5 POWER IN 6 POWER OUT max 15 units 7 CONTROL PANEL 8 SAFETY Fig 1 6 4 3 5 7 2 1 8 ...

Page 22: ...e presets 3200K 10000K LEDs average life span 75 000 hours Electronics and features Several DMX configurations selectable 3 4 5 6 and 10 channels for professional or simplified control ling 3 channels ARC mode RGB 3 channels HSV mode HSV Hue Saturation Value 4 channels ARC2 mode RGBW 4 channels ARCD mode RGB dimmer 5 channels AR2D mode RGBW dimmer 5 channels ARCS mode RGB dimmer strobe 6 channels ...

Page 23: ...secure the projector with the safety rope from falling down For this purpose fasten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm Adjust the projector and use the knob 2 to slightly release or tighten the locking mechanism of the bracket if is necessary Fig 2 1 2 Beam Diameter mt 0 2 4 6 8 Dist mt Diam mt Lux Center 0 52 1 05 1 58 2 10 2585 1232 660...

Page 24: ... switch 3 2 Basic Access control panel functions using the four panel buttons located directly underneath the LED Display fig 3 NOTE Never wait for more than 6 seconds to press the next button otherwise the procedure for setting enter into stand by mode MENU ENTER UP DOWN Used to access the menu or to return to a previous menu option Used to select and store the current menu or confirm the current...

Page 25: ...N IDOF ENTER UP DOWN ID00 ID50 AUTO ENTER UP AT8F AT1F DOWN AT1F AT1O ENTER SP01 T008 UP DOWN UP DOWN T001 T255 SP01 SP25 TEST ENTER UP DOWN TESR TESG TESb T065 ENTER UP DOWN X255 X000 TESW Soft DMX STAG ARC ARC2 ARCD AR2D ARCS AR2S HSV ENTER UP DOWN UP DOWN SFON SFOF 10 Ch 3 Ch 4 Ch 4 Ch 5 Ch 5 Ch 6 Ch 3 Ch ...

Page 26: ...he Master MAST The unit must be the first unit in line other units will work as slave SLAV with the same effect For the slave units adjust the DMX address 1 and set up STAG configuration Press the button MENU so many times until the display shows MAST or SLAV Press UP and DOWN to set the unit as master or slave Select the desired program see section 3 4 Use standard DMX cables to daisy chain your ...

Page 27: ...omatically assigned to the following addresses An example with the start address 33 is shown below Numberof DMXchannels Start address example DMX Address occupied Next possible start address for unit No 1 Next possible start address for unit No 2 Next possible start address for unit No 3 10 33 33 42 43 53 63 For addressing without ID addressing press the button MENU so many times until shows IDOF ...

Page 28: ...cable has to run longer distance is recommended to insert a DMX termination on the last unit 1 3 2 1 2 3 Pin1 GND Shield Pin2 Negative Pin3 Positive DMX INPUT XLR plug DMX OUTPUT XLR socket By selecting the corresponding ID address through channel 10 you can control each unit independently 3 11 Test Mode To set the custom balance of red green blue and white Press the button MENU so many times unti...

Page 29: ... of DMX 512 signals being reflected back along the cable when they reaches the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination is prepared by soldering a 120Ω 1 4 W resistor between pins 2 and 3 of the 5 pin male XLR connector as shown in figure ...

Page 30: ...5 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 Channel Function in STAG mode DMX value 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 COOL WHITE 0 100 000 255 6 COLOR MACRO 7 preset color effect 000 255 7 STROBE speed adjustable from slow to fast 000 255 8 AUTO program 8 programs 000 255 9 Program Fade In Out time Program run speed 000 128 129 255 10 ID ADDR ...

Page 31: ...55 4 BLUE 0 100 000 255 Channel Function in AR2D mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 WHITE 0 100 000 255 Channel Function in ARCS mode DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 ...

Page 32: ...DMX value 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 WHITE 0 100 000 255 6 STROBE 0 100 000 255 Channel Function in HSV mode DMX value 1 HUE 0 100 000 255 2 SATURATION 0 100 000 255 3 VALUE 0 100 000 255 ...

Page 33: ...ble condition and should be replaced immediately even when a small problem is detected The interior of the device should be cleaned annually using a vacuum cleaner or air jet It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socke...

Page 34: ......

Page 35: ...chi conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the unit in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Abstract General Guarantee Conditions Please remem...

Page 36: ...date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purchased by Acquistato da SURNAME COGNOME Dealer s stamp and signature Timbro e firma del Rivenditore NAME NOME ADDRESS VIA N CITY CITTA Purchasing date Data acquisto PROV ZIP CODE C A P ...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ... Music Lights S r l PROLIGHTS is a brand of Music Lights S r l company Via Appia km 136 200 04020 Itri LT ITALY tel 39 0771 72190 fax 39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company ...

Reviews: