4
INSTALLATION
The charge controller is designed to be mounted flush with the wall. Flush mounting
requires a rectangular cutout in the mounting surface with sufficient space (50–75mm)
depth behind, to accommodate the controller and wiring. The charge controller may
also be mounted to the wall without making a cutout. This is the quickest and easiest
mounting procedure, however, the controller will be raised from the wall.
WIRING DIAGRAM
Connection Procedures
(please refer to the connection diagram above)
1. Once the controller has been properly mounted select either Gel or Wet modes on the unit.
2. Connect the solar panel positive side to the charge controller “ARRAY” positive (+)
with a suitable wire. Be careful not to short circuit the solar array.
3. Connect the solar panel negative side to the charge controller “ARRAY” negative (-)
with a suitable wire.
4. Connect the battery positive side to the charge controller “BATTERY” positive (+)
with a suitable wire.
5. Connect the battery negative side to the charge controller “BATTERY” negative (-)
with a suitable wire.
164mm