VEHICLE JUMPSTARTING INSTRUCTIONS  

 

NOTE: Instructions for negatively earthed vehicles only. 

1. 

Charge your jumpstarter for 24 hours prior to first use and as soon as possible after each use. 

2. 

Before making any connections, check the jumpstarter battery status by pressing the red 
BATTERY STATUS button: 

 

Green LED:

  

Full Charge. Ready to use. 

 

Yellow LED:

   Medium charge. Ready to use, but recharge recommended.  

 

Red LED: 

 

Low charge. Need to be recharged and Not recommend to use. 

 

Flash Red LED:

 Need to be recharged immediately.

3. 

Turn your vehicle’s ignition to OFF before connecting the jumpstarter’s clamps to your vehicle. 

4. 

Connect the red positive (+) clamp to the positive (+) terminal of the vehicle battery, then 
connect the black negative (-) clamp to the negative (-) terminal of the battery or a non-moving 
metal part of the engine block. DO NOT CONNECT TO FUEL LINE. Always double check you 
have proper connections. 

5. 

Check Jumpstarter Status LED: 

 

Red:

   If illuminated check that the vehicle being jumpstarted is 12V, or the jumpstart 

 

cables are incorrectly connected onto the vehicle battery. This jumpstarter is suitable 

 

for 12V vehicles only.

 

Green:

  Ready to jumpstart.

 

None:

  If neither LED is illuminated, check that the clamps are correctly connected with good 

 

contact. If the LED’s remain unilluminated it may indicate that the vehicle’s battery 

 

is below 2.6V, the jumpstarter will only activate when connected to a battery above 

 

2.6V. In this circumstance ensure all connections are correct and then press the 

 

OVERRIDE button for 2 seconds to engage the jumpstarter.

6. 

Turn the vehicle’s ignition to ON and start the vehicle. 

7. 

After the engine has started leave the clamps connected for 40 seconds to allow the jumpstarter 
recovery to occur (optional). Then disconnect the black clamp and then the red clamp. 

8. 

Recharge jumpstarter.  

Note:

 With the use of RRT the jumpstarter does not require charging during the working day, 

however while not it use it should stored on the docking station to increase the life by 10–20%

 

CHARGING WITH AC ADAPTOR   

 

IMPORTANT: DO NOT POWER ANY APPLIANCE FROM THE JUMPSTARTER WHILE IT IS BEING 
CHARGED USING THE AC CHARGER. 

1. 

To charge, plug the output end of the AC adaptor into the charging socket (back of charging 
dock) and connect the AC adaptor to a 240VAC outlet and turn it ‘ON’. 

2. 

The Battery Status LED will illuminate orange when charging and green when the jumpstarter 
is fully charged. The jumpstarter will automatically stop charging and the jumpstarter will 
initiate maintenance charge mode keeping the battery fully charged and ready for use 
without the risk of overcharging. 

 

Charging time:

 4–6 hours if the battery is down to 50% of its capacity.

 

WHEN TO CHARGE  

 

To prolong the life of your jumpstarter battery it is recommended to charge the jumpstarter 
after each use. If the jumpstarter is not being used, it is recommended to leave the 
jumpstarter permanently on charge ensuring the battery is always maintained fully charged 
and ready for use. It is recommended to charge the jumpstarter before the first use as the 
jumpstarter is shipped only partially charged.

Summary of Contents for IS1500

Page 1: ...12 Volt 1500 Amp Intelli Start LITHIUM JUMPSTARTER P No IS1500...

Page 2: ...es when working with a lead acid battery The Jumpstarter contains a sealed non spillable Lithium Iron Phosphate battery It must be disposed of properly Ensure correct polarity when connecting to vehic...

Page 3: ...ger shelf life between recharging DOCKING STATION FOR 240V A slim and stable docking station is provided to allow the unit to be charged from a 240 Volt AC outlet AUTOMATIC CELL BALANCED CHARGE CONTRO...

Page 4: ...on Automatic solenoid control Recharging Via Charger Docking Station Source 112V 1A AC Adaptor Main Charge Internally cell balanced Constant Current Constant Voltage Maintenance Charge Constant Voltag...

Page 5: ...needs to be charged It might not have sufficient capacity to jumpstart the vehicle Red Flashing Internal battery voltage is too low and needs to be charged immediately Jumpstarter connected to the ca...

Page 6: ...re all connections are correct and then press the OVERRIDE button for 2 seconds to engage the jumpstarter 6 Turn the vehicle s ignition to ON and start the vehicle 7 After the engine has started leave...

Page 7: ...a number of reasons why the jumpstarter did not start your vehicle Check the following 1 Ensure the jumpstarter is fully charged Press the BATTERY STATUS button to check the condition of the battery...

Page 8: ...or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed The consumer must also deliver the or...

Reviews: