Projecta INTELLI-RV PM100 Instruction Manual Download Page 12

12

"FAULT" flashes twice every cycle.

Service battery high voltage alarm.

Service battery voltage

16V.

No Starter battery connected.

"FAULT" flashes twice every cycle.

Service battery high voltage alarm.

Service battery voltage

16V.

Starter batter has been connected.

"FAULT" flashes 3 times every cycle.

PM100 unit over temp alarm.

PM100 is working under PS mode.

"FAULT" flashes 3 times every cycle.

“Charge”flashes as 1 sec on then 2 sec off

PM100 unit over temp alarm.

PM100 is working under CHG mode.

"FAULT" flashes 4 times every cycle.

“Charge”flashes as 1 sec on then 2 sec off.

Bulk charging time out alarm.

"FAULT" flashes 5 times every cycle.

"Charge" flashes once every sec.

VCR anomaly alarm.

"FAULT" flashes 6 times every cycle.

Environment over temp alarm.

PM100 is working under PS mode.

"FAULT" flashes 6 times every cycle.

“Charge”flashes as 1 sec on then 2 sec off.

Environment over temp alarm.

PM100 is working under CH mode.

Please consult the distributor,

installer or PROJECTA

Please consult the distributor, 

installer or PROJECTA

PM100 will restart automatically

Check the ventilation and try to 

disconnect some of the less priority loads. 

If the fault still exists, please contact the 

distributor, installer or PROJECTA

1. Check the setting of the battery capacity. 

It should match the actual battery capacity.

2. Check the status of the battery. 

If the battery is dead, please contact the 

battery manufacturer or distributor.

Please consult the distributor,

installer or PROJECTA

PM100 will restart automatically.

PM100 will  stop charging immediately.

Mains

Troubleshooting

Str Bat. Charge Fault

Description

Solutions

"FAULT" flashes once every sec. 

Service battery low voltage alarm. 

10V

 Service battery voltage <10.5V. 

No starter battery connected.

The serivce battery needs to be charged 

as soon as possible.

The serivce battery needs to be charged 

as soon as possible.

"FAULT" flashes once every sec.

“Starter Bat.”flashes twice every sec.

Service battery low voltage alarm. 

10V

 Service battery voltage <10.5V. 

Starter batter has been connected, 

but VCR disconnect.

Summary of Contents for INTELLI-RV PM100

Page 1: ...INTELLI RV 12V POWER MANAGEMENT SYSTEM P No PM100 IMAGE TO BE UPDATED...

Page 2: ...tery Charger of stationery service battery 5 1 3 Battery Low Voltage Protection 5 1 4 Voltage Charging Relay VCR 6 1 5 Specification 6 2 STRUCTURE 8 3 OPERATION 9 3 1 Configuration 9 3 2 Wiring 9 3 3...

Page 3: ...t battery charger 12V 35A 20A for Charging Current Multiple battery charging stages to ensure the proper charging to battery High efficiency max 88 PFC available Battery charging relay 12V 60A 60A con...

Page 4: ...es are listed below AC Mains AC Mains AUX Starter battery Dominating Source F13 15A BAT BAT SBAT SBAT F12 1 L N _ BLVP Shunt Shunt VCR 15A DC 10A DC LOAD1 LOAD4 15A 4 LOAD5 LOAD10 10A 6 LOAD1 LOAD4 15...

Page 5: ...nd Recycle charging programs guarantees that the battery condition does not change despite being connect ed for a longer period PM100 has a built in low voltage protection relay It will disconnect the...

Page 6: ...elay Specification Connect voltage Connection delay time Disconnect voltage Disconnect delay time High voltage limit Charge Algorithms Battery type Start Voltage Bulk current Absorption Voltage Float...

Page 7: ...nect 2 6kgs 270x197x70mm steel case M4 Screw 16mm M3 Screw 4mm 50M 2KVDC 1min 1mA AS NZS 60335 2 29 CISPR14 Fan colling IP20 0mA Battery charger shutdown 10 Protection Fused outputs 10Ax6 15Ax4 YES Th...

Page 8: ...76 66 25 14 4 6 11 5 53 11 5 12 5 Hole size 14 8 4 2 Structure 8 260 120 66 103 10 2 103 196 9 120 38 5 5 260 270 70...

Page 9: ...6 0mm or 9 AWG 3 1 Configuration SIDE PANEL 1 2 146 9 70 70 3 4 5 6 7 8 9 10 11 No Label Definition Description 1 POWER 2 3 4 6 5 7 8 9 10 11 Starter Bat Starter battery connector Service battery con...

Page 10: ...le Flashes 4 times every cycle Flashes 5 times every cycle Flashes 6 times every cycle Service battery voltage high Over temp Heatsink Bulk charge timeout VCR anomaly Over temp Environment AC input ok...

Page 11: ...No starter battery connected Floating charge by Mains Grid Starter battery has been connected Charge flashes as 1sec on then 2 secs off Mains Grid is not available 10 5V Service battery voltage 16V N...

Page 12: ...onsult the distributor installer or PROJECTA Please consult the distributor installer or PROJECTA PM100 will restart automatically Check the ventilation and try to disconnect some of the less priority...

Page 13: ...NOTES...

Page 14: ...purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair...

Reviews: