INTELLI-RV

12V POWER MANAGEMENT SYSTEM

P/No. PM100

IMAGE TO BE UPDATED

Summary of Contents for INTELLI-RV PM100

Page 1: ...INTELLI RV 12V POWER MANAGEMENT SYSTEM P No PM100 IMAGE TO BE UPDATED...

Page 2: ...tery Charger of stationery service battery 5 1 3 Battery Low Voltage Protection 5 1 4 Voltage Charging Relay VCR 6 1 5 Specification 6 2 STRUCTURE 8 3 OPERATION 9 3 1 Configuration 9 3 2 Wiring 9 3 3...

Page 3: ...t battery charger 12V 35A 20A for Charging Current Multiple battery charging stages to ensure the proper charging to battery High efficiency max 88 PFC available Battery charging relay 12V 60A 60A con...

Page 4: ...es are listed below AC Mains AC Mains AUX Starter battery Dominating Source F13 15A BAT BAT SBAT SBAT F12 1 L N _ BLVP Shunt Shunt VCR 15A DC 10A DC LOAD1 LOAD4 15A 4 LOAD5 LOAD10 10A 6 LOAD1 LOAD4 15...

Page 5: ...nd Recycle charging programs guarantees that the battery condition does not change despite being connect ed for a longer period PM100 has a built in low voltage protection relay It will disconnect the...

Page 6: ...elay Specification Connect voltage Connection delay time Disconnect voltage Disconnect delay time High voltage limit Charge Algorithms Battery type Start Voltage Bulk current Absorption Voltage Float...

Page 7: ...nect 2 6kgs 270x197x70mm steel case M4 Screw 16mm M3 Screw 4mm 50M 2KVDC 1min 1mA AS NZS 60335 2 29 CISPR14 Fan colling IP20 0mA Battery charger shutdown 10 Protection Fused outputs 10Ax6 15Ax4 YES Th...

Page 8: ...76 66 25 14 4 6 11 5 53 11 5 12 5 Hole size 14 8 4 2 Structure 8 260 120 66 103 10 2 103 196 9 120 38 5 5 260 270 70...

Page 9: ...6 0mm or 9 AWG 3 1 Configuration SIDE PANEL 1 2 146 9 70 70 3 4 5 6 7 8 9 10 11 No Label Definition Description 1 POWER 2 3 4 6 5 7 8 9 10 11 Starter Bat Starter battery connector Service battery con...

Page 10: ...le Flashes 4 times every cycle Flashes 5 times every cycle Flashes 6 times every cycle Service battery voltage high Over temp Heatsink Bulk charge timeout VCR anomaly Over temp Environment AC input ok...

Page 11: ...No starter battery connected Floating charge by Mains Grid Starter battery has been connected Charge flashes as 1sec on then 2 secs off Mains Grid is not available 10 5V Service battery voltage 16V N...

Page 12: ...onsult the distributor installer or PROJECTA Please consult the distributor installer or PROJECTA PM100 will restart automatically Check the ventilation and try to disconnect some of the less priority...

Page 13: ...NOTES...

Page 14: ...purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair...