Projecta IDC25 User Manual Download Page 4

4

 

SPECIFICATIONS

  Operating Conditions

  Alternator Input Voltage 

 

9-32Vdc

  Maximum Solar Input Voltage 

 

23Vdc

  Maximum Input Current  

 

40A

  Input Current (No Load) 

 

20mA

  Back Drain on Auxiliary Battery  

 

9.5 – 10.5mA 

  External LED Output – Constant Current 

 

4 mA

  Output Current 

Input 9–11Vdc:  

 

20A 

   

Input 11V-32dc:  

 

25A

  Input Fuse Rating 

 

50A (Not supplied)

  Output Fuse Rating 

 

50A (Not supplied)

  Maximum Output Power 

 

385W

  Solar Input Turn On Voltage  

 

9V

  Size 

 

149 x 122 x 42 mm

 Weight 

 

800g

  Operating Temperature (Derated from 55

o

C) 

 -10 to +80

o

C  (Ambient Temperature)

  Charge Control

  Charge Type 

3 Stage

  Bulk *20A at 9-11Vdc, 25A at 11-32Vdc 

*Constant Current up to:

  

GEL 

AGM 

WET 

CALCIUM

 

 

14.1V 14.4V 14.7V 15.4V

  Absorption   

 Constant Voltage until current drop to 3.8A

  

GEL 

AGM 

WET 

CALCIUM

 

 

14.1V 14.4V 14.7V 15.4V

  Float 

Keep Constant Voltage at 13.7V 

  Equalisation 

3.8A Constant Current Charge up to 16V 

  (Calcium mode only)  

then hold for 1 hour (5 hour timeout)

  Battery Range

  Battery Capacity 

75-300Ah

  Type of Batteries Supported 

GEL, AGM, WET & CALCIUM

  Operating Mode

    

12V Vehicle 

 

24V Vehicle

  VSR Mode – Default (Ignition Override 

Turn on  

Turn off 

Turn on 

Turn off 

  Not Connected) 

13.4-20V 

<12.8V 

26.8-32V 

< 25.6V

  Low Voltage Mode – Ignition Override cable  

Turn on  

Turn off 

Turn on 

Turn off 

  connected to ignition switch (ignition on) 

12.2-20V 

<11.9V 

24.4-32V 

<24V

 Standards

  EMC 

 C-Tick, AS/NZS CISPR11:2011 Class B

  IP Rating 

 

IP67

Summary of Contents for IDC25

Page 1: ...25 Amp 3 Stage Switchmode INTELLI CHARGE DC SOLAR BATTERY CHARGER P No IDC25...

Page 2: ...circuit FEATURES The IDC25 DC DC charger is purposely designed for charging auxiliary batteries It includes all the features needed to maintain the auxiliary battery to its optimum condition and to p...

Page 3: ...ed with a 2 metre temperature sensor The sensor monitors the battery temperature and adjusts compensates the charger s output to prevent overcharging This is ideal for batteries used in warmer climate...

Page 4: ...11Vdc 25A at 11 32Vdc Constant Current up to GEL AGM WET CALCIUM 14 1V 14 4V 14 7V 15 4V Absorption Constant Voltage until current drop to 3 8A GEL AGM WET CALCIUM 14 1V 14 4V 14 7V 15 4V Float Keep...

Page 5: ...atus Solar LED Indicates solar input status Alternator LED Indicates alternator input status LED Battery Chemistry Display Indicates selected battery chemistry type DC Leads Temperature Sensing Cable...

Page 6: ...used for cable extension Recommended cable size for wiring Cable Size Alternator Input Cable Red 8mm2 8 B S Solar Input Cable Green 8mm2 8 B S Output Cable Grey 8mm2 8 B S Common Ground Black 8mm2 8...

Page 7: ...s close as possible to the Solar Panel positive terminal Then connect the Solar Panel negative terminal to the IDC25 Common Ground cable black colour Alternatively connect both Solar Panel negative te...

Page 8: ...nected The default Battery Chemistry is AGM Charging profile for each selection Bulk Constant Current up to 20A at 9 11Vdc GEL AGM WET CALCIUM 25A at 11 32Vdc 14 1V 14 4V 14 7V 15 4V Absorption Consta...

Page 9: ...rter Battery Red 8mm 2 Ground Chassis Black 8mm 2 Ignition override Blue 1 5mm 2 External LED Pink 1 5mm 2 Solar Green 8mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Tem...

Page 10: ...er Battery Red 8mm 2 Ground Chassis Black 8mm 2 Ignition override Blue 1 5mm 2 External LED Pink 1 5mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Temp Sensor mount to ba...

Page 11: ...dicator Earth Chassis Ground Chassis Black 8mm 2 External LED Pink 1 5mm 2 Solar Green 8mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Temp Sensor mount to battery casing...

Page 12: ...to the battery for long time Solid RED BLUE Output battery is reversely Check output cable Flashing Connected connection RED BLUE Overvoltage is detected Check auxiliary battery Flashing Flashing at o...

Page 13: ...ates the auxiliary battery is in full charged Q I have connected the charger properly but the INPUT LED does not come on A Check the cable size The IDC25 is designed to power on and charge from an inp...

Page 14: ...nough to ruin your battery If after twelve hours of charging your battery is still accepting charge you should test the cells using a hydrometer If one reading is lower than the rest it indicates a fa...

Page 15: ...15 NOTES...

Page 16: ...must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a wa...

Reviews: