background image

10

  SOFTWARE OPERATION

1.  Select result to download then press USB key
2.  Display will indicate ‘download mode’ is active
3.  Launch BLT700 software by clicking desktop icon
4.  Main screen will display as shown
5.  Before proceeding confirm a COM port has automatically been selected e.g. COM-4
6.  Click icon to download data from analyser into computer
7.  Enter any additional details required. Date, name, test reference e.g. licence plate battery model, 

battery rating in Amps

8.  Click icon to add details to test report
9.  Click icon to create Header/Footer information
10. Click icon to Print results
11. Click icon to Save results

BLT700

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

Summary of Contents for BLT700

Page 1: ...12 VOLT BATTERY ELECTRICAL SYSTEM ANALYSER P No BLT700...

Page 2: ...ative connection 4 USB connection 5 USB button 6 EXIT BACK button 7 Directions buttons 8 ENTER button 9 PRINT button 10 Status indicator GREEN 11 Power indicator RED 12 Thermal printer INSTALLING PAPE...

Page 3: ...is option to add more test results to those last viewed or stored in memory 3 View print results Select results to view then press Enter Results can then be printed by pressing PRINT button 1 Time Dat...

Page 4: ...seconds will delete ALL results in memory 5 Select battery range After selecting new test or continue testing select a suitable battery range 1 HIGH RANGE e g Car Van 2 LOW RANGE e g Motorcycle 6 Sel...

Page 5: ...d If the battery voltage is low below 12 volts it may still be tested but a warning will be given prior to starting the test 1 Select battery type Select battery type to be tested 2 Select battery rat...

Page 6: ...re charged before testing Select option 2 if battery was re charged before testing 9 After analysis results are displayed 1 Diagnosis refer icons 2 Battery Volts 3 Rated CCA 4 Actual CCA 5 Conductanc...

Page 7: ...ds 4 Press Enter to begin analysis 5 After analysis results are displayed 1 Ground connection normal 2 High resistance clean tighten connections 3 Ground not detected repeat procedure STARTER TEST Sel...

Page 8: ...nter to continue 4 Switch on main electrical loads in vehicle then press Enter 5 Rev engine to 2000RPM press Enter then hold revs for 10 seconds 6 After analysis results are displayed 1 Max allowable...

Page 9: ...d Solid power connected SOFTWARE INSTALLATION 1 Make sure BLT700 is not connected to computer 2 Insert CD into computer and open driver folder 3 Launch driver installer file 4 Follow instructions to i...

Page 10: ...confirm a COM port has automatically been selected e g COM 4 6 Click icon to download data from analyser into computer 7 Enter any additional details required Date name test reference e g licence plat...

Page 11: ...11 NOTES...

Page 12: ...purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair...