WARNINGS

Following instructions must be consulted in order to obtain a correct installation, 

use and maintenance of product, as well as ensuring your safety.

Still retain this documentation for future reference, even for those who will later 

work on the lamp for any reason.

FEATURES

Industrial LED projector made with a PVC structure, an aluminum heatsink and a 

glass lens. The overall dimensions is  175mm x 50mm x 100mm height

• LED light source

• LED Colour BLUE or RED

• Absorption MAX 2,0A (Safety Bar 20 BLUE), 1,7A (Safety Bar 20 RED)

• Frequency: 50-60 Hz

• Input voltage From 12Vdc to 48Vdc

• Consumption 24W (Safety Bar 20 BLUE), 20W (Safety Bar 20 RED)

• Appliance with isolation class III

• Max nominal ambient temperature: +50°C

• Min nominal ambient temperature: -30°C

• IP Protection class: IP65

• Use of heat-resistant power cables, interconnection cables or external wiring 

till +90°C

Features of the power connector

• Number of poles 2

• Contact marking 1 + and 2 -

• Type of connection crimping

• Operating current max. 14A

• Operating voltage max. 50V

• Protection against solid/water IP67

• Wire cross-section min 0,75mmq : max 1,5mmq

• Cable diameter min. 3mm - max 5mm

SAFETY RULES

Always switch off the fixture before carrying out any cleaning.

Before taking any action on it make sure it has completely cooled.

Fixture suitable for installation on normally inflammable surfaces.

Designed for direct illumination of horizontal and vertical surfaces.

LED  light  source:  it  is  recommended  not  to  fix  the  beam  to  avoid  possible 

permanent damage to the retina.

Device suitable for indoor and outdoor use. The light source of this appliance is 

not replaceable; when the light source eaches the end of life, the whole luminaire 

must be replaced.

Electrical  part  consists  of  a  stabilized  power  supply:  built-in  protection 

circuit shuts down the device in case of open circuit, short circuit, overload or 

overheating; the power supply may not be turned on even after the fault. In this 

case, contact the manufacturer.

Conductor cross section min. min 0,75 mmq - max 1,5mmq.

Operating temperature: min. -30°C max. +50°C.

The luminaire must be positioned in such a way that a prolonged observation of 

the luminaire is not possible at a distance of less than 4 meters.

Notes for the disposal of the device, see RAEE standards.

HOW TO USE

Open the box, extract the fixture carefully and store up the packaging.

Fix the lamp on the structure of the forklift, thanks to the special bracket.

The  lamp  has  at  its  output  a  2-pole  male  connector,  model  SUPER  SEAL 

(rubber cod 0-0880810-1 + connector code 0-0282104-1 + male terminals cod 

0-0282109-1).  In  the  kit  of  the  lamp  there  are  the  SUPERSEAL  counterpart 

(code 0-0282080-1) and relative rubber pad (code 0-0880810-1), with the female 

crimping terminals (cod 0-0282110-1); see section of the conductors and cable 

diameter in the specifications in the manual. The components of the kit must 

be mounted on the cable that will power the lamp (from 12Vdc to 48Vdc);j then 

connect the two male and female connectors pressing, until you hear the “click” 

that indicates the correct connection of the two counterparts.

If the external flexible cable of this appliance is damaged, it must be replaced 

exclusively by the manufacturer.

Do  not  cover  the  device  with  plastic  sheets,  cloths,  tissues  cause  it  has  to 

dissipate the heat produced by the light source.

For cleaning and maintenance always use a damp cloth without any solvents or 

acids. For your safety, do not attempt to modify the unit.

The  information  contained  in  the  following  documents  are  subject  to  change 

without  any  notice  by  the  company.  The  company  guarantees  the  conformity 

of  the  products  with  the  applicable  European  safety  and  EMC.  We  accept  no 

responsibility for any damage to the product, to things and/or people, due to 

improper  installation  and/or  because  of  changes  made  to  the  device,  using 

accessories and/or electrical/electronic components are not suitable. It’s strictly 

forbidden  any  reproduction,  even  partial,  of  the  information  contained  in  this 

leaflet.

The  reproduction,  even  partial,  of  the  contents  of  this  leaflet  is  strictly 

forbidden.

Summary of Contents for SAFETY BAR 20 EVO

Page 1: ...MANUALE D USO USER MANUAL SAFETY BAR 20 EVO ...

Page 2: ...so di circuito aperto corto circuito sovraccarico o surriscaldamento l alimentatore potrebbe non riaccendersi anche dopo aver eliminato il guasto Sezione conduttori di alimentazione min 0 75mmq max 1 5mmq Temperatura di esercizio min 30 C max 50 C L apparecchio di illuminazione deve essere posizionato in modo che non sia prevista un osservazione prolungata dell apparecchio ad una distanza inferior...

Page 3: ...ase contact the manufacturer Conductor cross section min min 0 75 mmq max 1 5mmq Operating temperature min 30 C max 50 C The luminaire must be positioned in such a way that a prolonged observation of the luminaire is not possible at a distance of less than 4 meters Notes for the disposal of the device see RAEE standards HOW TO USE Open the box extract the fixture carefully and store up the packagi...

Page 4: ... the Council of the Europen Union Apparecchio che può essere installato su superfici normalmente infiammabili Temperatura di funzionamento normale non superiore a 90 C Temperatura di funzionamento in caso di guasto non superiore a 130 C EN 60598 1 ED 2000 A11 2000 A12 2002 A1 2006 Fixture suitable for direct mounting on normally inflammable surfaces Normal operating temperature not exceeding 363K ...

Page 5: ...60598 1 cl 5 6 EN 60598 2 5 heat resistant UTILIZZO DELL APPARECCHIO HOW TO USE SAFETY BAR 20 EVO Distanza minima dagli oggetti illuminanti 2 25 metri Minimum distance from luminaires 2 25 meters Alimentazione in corrente continua DC power supply Uso di cavi di alimentazione di interconnessione o di cablaggio esterno resistenti al calore Power cables interconnection cables or external wiring heat ...

Page 6: ...nte a quanto previsto nelle Condizioni di Garanzia ricevute al momento dell acquisto e alle schede tecniche consultabili sul sito www progtech it Grazie per il vostro acquisto WARRANTY This is to certify that the product purchased has been made entirely in Italy by CABLOTECH using high quality materials and with the aid of specialized manufacturing it was finally subjected to a careful process of ...

Page 7: ...PROGTECH srl via Milano 60 24040 Bonate Sopra Bg T 39 035 04 46 251 info progtech it www progtech it ...

Reviews: