ProgressiveIndustries.net | 919-267-6964
6
INSTRUCTION MANUAL:
ELECTRICAL MANAGEMENT SYSTEM (EMS)
Error Code Chart
E 0 =
Normal Operating Condition
E 1 = Reverse Polarity (hot and neutral wires reversed)
E 2 =
Open Ground (no ground wire connection)
E 3 =
Line 1 High Voltage (line 1 voltage above 132V)
E 4 =
Line 1 Low Voltage (line 1 voltage below 104V)
E 5*=
Line 2 Voltage High (line 2 voltage above 132V)
E 6*=
Line 2 Voltage Low (line 2 voltage below 104V)
* Codes only apply to EMS-PT50X models
You should report an
E 1
,
E 2
,
E 3
,
E 4
,
E 5
or
E 6
Error Code directly to the Campground
Management. Our Tech Support Team will not be able to assist you if you receive one
of these Error Codes.
E 7 =
Line Frequency High (line frequency above 69 Hz)
E 8 = Line Frequency Low (line frequency below 51 Hz)
E 9 =
Data Link Down (does not apply to EMS-PT models)
E 10 =
Replace Surge Protector Module (call technical support)
Contact Progressive Industries Tech Support for an
E 7
,
E 8
,
E 9
or
E 10
Error Code.
NOTE:
If the EMS shuts down power to the RV it will indicate a PE Code (Previous Error)
following the Error Code. This indicates why the unit shut down. To determine the
meaning of a PE code, ignore the letter P (i.e. PE4 actually indicates an
E 4
Error Code
or Line 1 Low Voltage (line 1 voltage below 104V). See above Error Codes.
Example:
The EMS shuts down power for low voltage on Line-1 and then power is
restored. The Error Code reads
E 0
with a previous error code PE4 indicating low
voltage which is why the unit shut down previously. The PE code will clear when power
is disconnected from the EMS.