Progressive Dynamics Inteli Power 9200 PD9200 SERIES Owner'S Manual Download Page 1

PD9200 SERIES 

OWNERS MANUAL 

PROGRESSIVE DYNAMICS, INC. 

POWER CONVERTER LIMITED WARRANTY 

 

I. 

LIMITED WARRANTY:  Progressive Dynamics, Inc. warrants its power converter to be free from defects 
in material or workmanship under normal use and service; and limits the remedies to repair or replacement.

 
II.  DURATION:  This warranty shall extend for a period of two years from the original date of purchase, and 

is valid only within the continental limits of the United States and Canada. 

 
III.  WARRANTY EXCLUSIONS: This warranty specifically does not apply to: 
A.  Any power converter which has been repaired or altered in any way by an unauthorized person or service 

station; 

B.  Damage caused by excessive input voltage, misuse, negligence or accident; or an external force; 
C.  Any power converter which has been connected, installed or adjusted or used other than in accordance with 

the instructions furnished, or has had the serial number altered, defaced or removed; 

D.  Cost of all services performed in removing and re-installing the power converter; and 
E.  ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL 

DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE PRODUCT.  THIS 
INCLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES
FOR PERSONAL INJURY.  THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, 
INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. 

 
IV.  PROOF OF PURCHASE:  A warranty claim must be accompanied by proof of the date of purchase. 
 
V.  CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied the 

following information at the address listed below: 

 

 

 

 

 

 

 

 

A. 

Name and address of the claimant; 

 

 

 

B. 

Name and model of the power converter; 

C. 

Name, year and model of the recreational vehicle in which the power converter 
was installed; 

 

 

 

D. 

Date of purchase; and 

 

 

 

E. 

Complete description of the claimed defect. 

 

 

 

 

 

Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal 
use and service,) the power converter shall be shipped postage prepaid to Progressive Dynamics, Inc. together 
with proof of purchase.  The power converter will be repaired or replaced and returned postage prepaid. 

 

Progressive Dynamics Inc. 

507 Industrial Rd. 

Marshall, MI 49068 

269.781.4241, Fax 269.781.7802 

[email protected] 

www.progressivedyn.com

 

TM

109821D

Summary of Contents for Inteli Power 9200 PD9200 SERIES

Page 1: ...OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAMAGES FOR PERSONAL INJURY THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IV PROOF OF PURCHASE A warranty claim must be accompanied by proof of ...

Page 2: ...ls have been shorted If this condition should occur the converter first limits the current Should the condition continue to exist the converter then reduces the current output within thousandths of a second The INTELI POWER 9200 was designed to protect itself Once the short circuit has been corrected the INTELI POWER 9200 will automatically return to normal operating conditions THERMAL PROTECTION ...

Page 3: ...s 14 4 Volts Boost Mode Returned the battery to 90 of full charge in approximately 8 hours The battery reached full charge in approximately 11 hours 13 6 Volts Normal Mode Required 40 hours to return the battery to 90 of full charge and 78 hours to reach full charge 13 2 Volts Storage Mode Required 60 hours to return the battery to 90 of full charge and 100 hours to reach full charge The integrate...

Page 4: ... mode the microprocessor automatically increases the output voltage to 14 4 volts for 15 minutes every 21 hours This will help to reduce the buildup of sulfation on the battery plates NOTE Your Inteli Power 9200 Converter Charger may have been supplied with a Remote Pendant The Remote Pendant is optional on OEM units but is included with all retail models and plugs into the accessory port of the 9...

Page 5: ...hort Circuit Trace RV Circuits for possible fault Unit has shutdown due to overheating Check air flow Allow unit to cool Check input voltage Converter will shut down if the input voltage exceeds 132 Volts Unit has shutdown due to over voltage Also see Item 5 below Correct Input Voltage 2 External Fuses Blown Reverse Battery Hook Up Correct Hook up and replace Fuses with same type and rating 3 Conv...

Page 6: ...x 8L x 9W Weight 5 8lbs PD9270 Input 105 130 VAC 60 Hz 1250 Watts Output 13 6 VDC 70 Amps Dimensions 3 6H x 8L x 9W Weight 5 8lbs PD9280 Input 105 130 VAC 60 Hz 1300 Watts Output 13 6 VDC 80 Amps Dimensions 3 6H x 11 5L x 9W Weight 7 5lbs CAUTION RISK OF FIRE Chassis bonding wire must be a separate wire ran directly from the Grounding Lug provided on the converter DO NOT connect Output Negative to...

Page 7: ...tilisation DE PLAISIR OU D Autres DOMMAGES DE CHOSE FORTUITE PROVENANT DE L Utilisation DE OU DE L Incapacité D UTILISER LE PRODUIT CECI INCLUT DES DOMMAGES À LA PROPRIÉTÉ ET JUSQU AU DEGRÉ AUTORISÉ PAR LA LOI AUX DOMMAGES POUR DES BLESSURES CETTE GARANTIE EST AU LIEU DE TOUTES AUTRES GARANTIES Y COMPRIS LES GARANTIES IMPLICITES DE LA VALEUR MARCHANDE ET DE LA FORME PHYSIQUE POUR UN BUT PARTICULIE...

Page 8: ...on de l obstruction de circulation d air ou d une inexacte installation d Inteli power 9200 diminuer la sortie reviendra en même temps que l unité revienne à la température de fonctionnement normale La pleine capacité de sortie retournera comme l unité refroidit REFROIDISSEMENT DE COMPOSANT INTERNE Les INTELI POWER séries de convertisseurs sont équipés d un ventilateur de vitesse variable Le venti...

Page 9: ...RÉGULIÈRE QUAND LE CHARGEUR DE BATTERIE EAT CONSTAMMENT COMMECIE À UNE SOURCE D ENERGIE CELUI CI SE DECHARGECA DU GAZ ET PERDRA DU FLUIDE MODE DE NORMALE La tension de rendement a placé à 13 6 volts de C C Cette tension fournit bon chargeant des taux et la basse utilisation de l eau MODE DE POUSSÉE Si le convertisseur sent que la tension de batterie a chuté au dessous de l préréglez de niveau la t...

Page 10: ...arge complètement la batterie en toute sécurité Lumière Clignotant Lentement toutes les 5 6 secondes Indique que le convertisseur est en Storage Mode mode de charge complète et que la tension de sortie est baissée à 13 2 Dans ce mode la batterie RV véhicule de caravaning charge entièrement et elle est maintenue à son niveau de charge maximum INTERRUPTEUR MANUEL L interrupteur manuel a été fourni p...

Page 11: ...on appropriée Vérifiez le renversement de la polarité Fusibles Externes Soufflés Par remplacez les fusibles par le même type et calibre Court circuit Circuits de la trace RV pour possibité le défaut L unité a l arrêt dû à la surchauffe Contrôlez la circulation d air Permettez à l unité de se refroidir Contrôlez la tension d entrée 1 Aucune Sortie L unité a s arrêt dû à une sur tension voir égaleme...

Page 12: ...imensions 3 6H x 8L x 9W Poids 5 8lbs PD9280 Entrée 105 130 VAC 60 Hz 1300 Watts Sortie 13 6 VDC 80 Ampères Dimensions 3 6H x 11 5L x 9W Poids 7 5lbs LE RISQUE DE PRUDENCE DE FEU le Châssis adhéérer le fil doit être un fil séparé a couru directement au châssis de la Patte de mise à terre fournie sur le côté du convertisseur Ne pas connecter le Production négatif à l utilisation de châssis fil pare...