Building In
30 mm
55 mm
40-50 mm
min. 650 mm
490 mm
min. 450 mm
270 mm
A
B
A.
supplied seal
B.
supplied brackets
CAUTION!
Install the appliance
only on a worktop with flat
surface.
Possibilities for insertion
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A.
Removable panel
B.
Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from
the unit.
TECHNICAL DATA
Cooking zones specification
Cooking zone
Nominal Power (Max heat set-
ting) [W]
Cooking zone diameter [mm]
Middle front
1000
145
Middle rear
1500
180
For optimal cooking results use cookware
not larger than the diameter of the cooking
zone.